Precision Server Rack Mount Air Conditioner Rack Mount AC Unit

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M13

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $500.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

9KW Server Rack Mount Air Conditioner

,

Precision Server Rack Mount Air Conditioner

,

9000W rack mount ac unit

Cooling Capacity:
3.5KW-9KW
Color:
Black/Grey White/other Custom Colors
Mounting:
Rack Mountnting
Power:
1N-220V-50Hz,110v/50hz/60hz
Air Flow:
750M3/H
Application:
Cabinet/ Intelligent Project And Medium & Small Sized Enterprise
Cooling Capacity:
3.5KW-9KW
Color:
Black/Grey White/other Custom Colors
Mounting:
Rack Mountnting
Power:
1N-220V-50Hz,110v/50hz/60hz
Air Flow:
750M3/H
Application:
Cabinet/ Intelligent Project And Medium & Small Sized Enterprise
Precision Server Rack Mount Air Conditioner Rack Mount AC Unit

Rack Type Precision Air Conditioner for rack servers and blade servers (3.5KW -9KW )

 

Product Introduction                               

COOL RACK Series rack-mounted air conditioner is a cabinet-level temperature control product specially designed for integrated cabinets data center, modular data center or high heat density data centers. It can be placed in the cabinet close to the heat source and can accurately handle the output of the equipment in the cabinet. The high sensible heat can effectively prevent the generation of local hot spots, reduce the return air distance, increase the return air temperature, and improve the energy efficiency ratio.

 

Benefits                                                     

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 0

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 1

 

Features                                                       

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 2

1. Supply the air closely, cooling the heat equipment directly, and more efficient for the cooling effect; close cold & hot channel, reduce energy loss, save energy consumption, and to create economic value for the user.

2. Can choose environment friendly refrigerants with variable frequency compressor and control system, control the cabinet temperature with accurate and intelligent, thus can achieve environment protection and social benefits.

3. With large range of cooling capacity, our planning products include fixed frequency compressor system: 3.5kw, 5kw and 9kw cooling capacity, inverter compressor and control system corresponding to 1-9kw adjustment capacity to meet the existing cabinet cooling needs and a single cabinet integration is getting higher and higher, the heat of growing trend war.

4. Variety installation methods, flexible choosing:

Split cabinet installation (CI**):Suitable a cabinet which have free space inside the cabinet, the indoor air conditioner installed inside the cabinet directly, do not take up external space, to ensure that the cabinet looks cleaning and beautiful.

Integral cabinet top installation (CT**): suitable for the cabinet that has relatively compact layout, the air conditioner installed in the top of the cabinet, and supply air cooling directly to the cabinet, do not take up internal space, can be installed other equipment as well, but must consider the cabinet’s height and the ventilating heat dissipation around the cabinet.

Integral cabinet side installation (CS**): Installed on the side of the cabinet, open a pore side of the air conditioner, and supply air to the cabinet. And the air conditioner is an integral type structure, no need to connect the pip for the installation site, but it must need good ventilation conditions since the condensation heat releasing around the cabinet.

5. The air conditioner configured after bending centrifugal fan, large air volume, small air enthalpy difference, high SHR air supply, suitable for server cooling characteristics;
6. High reliability, high lifespan;

Well-equipped, adopt well-known brand for fan, compressor, refrigeration accessories; multi-fan configuration, easy for replacement and maintenance.
7. All-weather operation, supply cooling annual, operating ambient temperature: -45℃~45 ℃;

8. With RS485 communication and monitoring functions;

 

 

Scope of Application                                    

  • Micro Data C enter
  • Single row cabinet
  • Modular Computer Rooms
  • Medium and high heat density computer room
  • Modular Data Center
  • IT Rack for Blade Servers
Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 3

                     

Air Supply Method                                         

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 4

 

Indoor Unit Parameters                                            

Model-CJA 0003 0005 0007 0012
Phase/Function 1.5P,Single Phase 2P,Single Phase 3P,Single Phase 5P,Single Phase
Parameters
Cooling capacity kW 3.5 5 7.5 12.5
Sensible cooling capacity k W 3.5 5 7.5 12.5
Air volume m³/h 800 1150 1600 2300
Sensible heat ratio % 100 100 100 100
Heating kW (Option) 1 1 2 3
Maximum operating current A 15 15 25 34
Power Cord Cable Specifications mm 3×2.5 3×2.5 3×4 3×6
Indoor/outdoor unit shut-off valve
Refrigerant gas pipe φ mm 12.7 12.7 12.7 15.88
Refrigerant liquid pipe φ mm 9.52 9.52 9.52 9.52
Indoor unit structural parameters
Dimension:W×D×H mm 442×714×175 (4U)
442×714×218 (5U)
442×714×218 (5U) 442×714×351 (8U) 442×714×440 (10U)
Outdoor Unit
Type-CJT 3005 3005 3008 3013
Quantity 1 1 1 1
Note 1: Under standard conditions, the indoor dry bulb temperature is 37°C, the wet bulb temperature is 21°C, and the outdoor dry bulb temperature is 35°C;
Note 2: The above table is only part of the parameters, the specific configuration is subject to the actual purchase of the nameplate.

 

Outdoor Unit Parameters                                        

Type- CJT 3005 3005 3008 3013
Power supply 220Vac/1Ph/50Hz
Installation Vertical
Speed mode Stepless speed regulation
Noise dBA 54 55 56 58
Rated current A 6 6 10 15
Power Cord Cable Specifications mm 4×1.5 4×1.5 4×2.5 4×4
Communication cable specificati mm (with shielding function) on 3×1 3×1 3×1 3×1
Structural parameters of outdoor unit
Dimension:W×D×H mm 840×285×610 840×285×610 880×360×800 930×390×1270

 

① The power cord of the outdoor unit must be connected from the indoor unit;
②The ex-factory unit is not equipped with a 4.3-inch touch screen, and needs to be purchased separately. 

 

Certificates                                                  

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 5

 

Factory Details                                                      

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 6

 

Packing & Delivery                                                   

 

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 7

 

Cases                                                  

Precision Server Rack Mount Air Conditioner Rack Mount AC Unit 8