12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: M13

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

12KW Computer Room Air Conditioning Unit

,

R407C Computer Room Air Conditioning Unit

,

12000W CRAC HVAC

Cooling Capacity:
12KW
Mounting:
Floor Standing
Condition:
New
Type:
Precision Air Conditioning Unit( Air Cooled )
Operating Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Cooling Capacity:
12KW
Mounting:
Floor Standing
Condition:
New
Type:
Precision Air Conditioning Unit( Air Cooled )
Operating Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting

Computer Room Air Conditioning Dual Air Cooled System 12KW

 

Product Introduction                        

The Cool-Smart Series computer room air conditioner is designed for small and medium-sized computer rooms, base stations, equipment rooms, etc., Cool-Smart has the characteristics of high air volume and small enthalpy with high reliablity , high efficiency, long working life and energy saving advantages .

 

 

Applications                          

  • IT Equipment Room
  • Small Data Center
  • Industrial Clean Room
  • Constant Temperature and Humidity Process Workshop
  • Laboratory
  • Electric Power Equipment Room
  • Railway Subway Machine Room
  • Base Station and Small Telecom Switch Room
  • Medium&Small Telecom Switch Room

 

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 0

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 1

 

Technical Features                               

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 2

High reliability

Provide Constant temperature & humidity, cleanness precision environment to ensure the main equipment in good running condition

24-hour running design guarantee main equipment operation safety

All units had passed a severe running test before delivery, which can ensure units’ high reliability.

 

High energy efficiency

SHR (sensible heat ratio) is larger than 90%.

Compressor EER is larger than 3.1

Optimal CFD air duct design: minimum air duct resistance & minimumfan power

Inverter IDU: high efficiency & long working life

Advanced control logic: avoid competitive running and output cooling capacity according to actual cooling capacity demand.

 

Easy maintenance

Front panel maintenance: all maintenance operation can be finished

from the front panel

Remote control: convenient management & maintenance

 

Multiple choice

Wide range of cooling capacity: 5.5kW~20.5kW

Multiple types:cooling only, cooling & electrical heating, constant temperature & humidity.

Multiple cooling modes:air cooled, Freon pump, water cooled & glycol cooled.

Multiple air supply modes:cap tuyere supply, air duct supply,

floorboard supply, etc.

Multiple refrigerant types:R22, R407C, R410A

Wide operation temperature range(ambient air temperature): standard type(-20℃~50℃), low temperature type(-40℃~50℃)

Customization:fit into your special requirements

 

 

Technical Parameter                              

                 

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

Certificates                                          

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 3

 

Factory Details                                            

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 4

 

Packing & Delivery                                         

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 5

 

Case                                                    

12KW Computer Room Air Conditioning Unit with Dual Air Cooled System and Floor Standing Mounting 6