ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: CYAT50

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Get Best Price
Highlight:

ISO9001 server room AC unit

,

aircon for server room

,

50kw pac air conditioner

Cooling Capacity:
50kw
Condition:
New
Mounting:
Floor Standing
Type:
Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Product Name:
Precision Air Conditioning
Precision Air Conditioning:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey White/other Custom Colors
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Compressor:
Scroll Compressor
Cooling Capacity:
50kw
Condition:
New
Mounting:
Floor Standing
Type:
Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Product Name:
Precision Air Conditioning
Precision Air Conditioning:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey White/other Custom Colors
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Compressor:
Scroll Compressor
ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Floor Standing Data Center PAC Server Room Precision Air Conditioner

 

Product Introduction                                 

Precision air conditioning units

1. Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer equipment.

2. Unlike comfort air conditioning, close control systems must operate constantly 24/7 requiring high reliability and minimal power consumption.

3. Quiet, compact and energy efficient equipment that can be configured to needed requirements.

 

Benefits                                                    

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit 0

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit 1

 

Advantages                                          

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit 2

 

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.

 

Applications                                   

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber
ISO9001 Floor Standing Data Center Server Room Air Cooling Unit 3

Technical Features                             

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit 4

 

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

 

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water

cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer

working life.

Advanced control logic can effectively avoid competitive running

and output cooling capacity according to actual cooling capacity

demand.

 

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether

air filters was blocked or not.

 

Multiple types

Wide capacity range:

air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).

Multiple cooling mode:

air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Multiple air supplying modes:

cap tuyere mode, air duct mode, floorboard mode.

Multiple refrigerant types: R410A, R407C, R22.

Wide ambient air temperature rang:

standard range(-20℃~50℃),low temperature range(-40℃~50℃).

Technical Parameters                               

 

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 