products

Space Saving In Row Air Conditioner For Data Center IDC Cooling System

Basic Information
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: CYA,M08,CR012
Minimum Order Quantity: 1set
Price: 1800-30000USD
Packaging Details: Packed in plywooden case, standard export package
Delivery Time: 10-25 working days
Payment Terms: T/T, L/C
Supply Ability: 300 PCS PER MONTG
Detail Information
Cooling Capacity: 20-50KW Condition: New
Mounting: Floor Standing Type: InRow Unit
Operating Voltage: 380/400 VAC,230 VAC,220V Warranty: 1 Year
Product Name: Inrow Precision Air Conditioning Refrigerant: R22(R407C/R410A)
Application: Data Center, IT Room Color: Black/Grey White/other Custom Colors
Fan Type: Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan Power: 3N-380V-50Hz,220v/50hz/60hz
Airflow: 2000~50000 M3/h Voltage: 380v/220v,220V/380V,380V/415V
High Light:

220V in row air conditioner

,

Space Saving in row air conditioner

,

50000m3/h datacenter air conditioner


Product Description

Space Saving In Row Air Conditioner For Data Center IDC Cooling System

 

Product Introduction                                   

CoolRow is a in-row cooling solution commonly used in data centers requring higher density cooling with greater efficiency and capacity. The unit is placed beteween the servers in a row for offering cooling close to the heat load, the horizontal airflow pattern supports hot aisles and cold aisles configeration. CoolRow improves the efficiency of the overall cooling systems and ensures the steady room temperature for precise operation.

 

Feature & Benefits                           

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 0

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 1

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 2

Application Range                       

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 3
  • High power density Data center
  • Small and medium scale dat center
  • Single rack with power larger than 3kW
  • Modular Data Center
  • Container type DC
  • DC with low PUE

 

Advantages                         

High efficiency- EVO intelligent control system

Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.

 

High Efficiency-DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability.

 

High Efficiency-Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

 

High Efficiency-Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Fast response speed, realizing precise refrigeration

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 4

 

Technical Parameter                               

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                            

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 5

 

Factory Details                                   

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 6

 

Packing and Delivery                                    

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 7

 

Case                                               

Space Saving In Row Air Conditioner For Data Center IDC Cooling System 8

 

 

 

 

 

 

Contact Details
Janet

WhatsApp : +8618326091011