Floor Standing In Row Air Conditioning Unit IDC Cooling System

Basic Information
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: CR040A, CR012A
Minimum Order Quantity: 1set
Price: 1800-30000USD
Packaging Details: Packed in plywooden case, standard export package
Delivery Time: 10-25 working days
Payment Terms: T/T, L/C
Supply Ability: 300 PCS PER MONTG
Detail Information
Cooling Capacity: 20-50KW Condition: New
Mounting: Floor Standing Type: Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
After-sales Service Provided: Engineers Available To Service Machinery Overseas Operating Voltage: 380/400 VAC,230 VAC,220V
Warranty: 1 Year Product Name: IDC Cooling System
Refrigerant: R410A Application: IDC, Data Center , Computer Room
Color: Black/Grey White/other Custom Colors Power: 3N-380V-50Hz,220v/50hz/60hz
Airflow: 2000~50000 M3/h Voltage: 380v/220v,220V/380V,380V/415V
High Light:

CE In Row Air Conditioning Unit

,

Floor Standing In Row Air Conditioning Unit

,

20kw data center air conditioner


Product Description

Floor Standing In Row Air Conditioning Unit IDC Cooling System

 

Product Introduction                              

Close-coupled cooling, row-oriented architecture, and in-row cooling are some common names used to describe row-based cooling in data centers. Throughout this paper the term row cooler1 will be used to describe this architecture. In addition, the term “pod” will be used to describe how row coolers are typically deployed (see side bar for definition).

 

 

 

Application                                       

  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction
Floor Standing In Row Air Conditioning Unit IDC Cooling System 0

Floor Standing In Row Air Conditioning Unit IDC Cooling System 1

Advantages and Features                       

Floor Standing In Row Air Conditioning Unit IDC Cooling System 2

High efficiency- EVO intelligent control system

  • Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.

High Efficiency-DC Inverter Compressor of DX System

  • Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

High Efficiency-Backward Centrifugal EC Fan

  • Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;
  • Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;
  • Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;
  • Soft start function, low starting current; Easy maintenance design.

High Efficiency-Electronic Expansion Valve

  • Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;
  • Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;
  • Fast response speed, realizing precise refrigeration.

 

Floor Standing In Row Air Conditioning Unit IDC Cooling System 3

Air Supply Method                               

Floor Standing In Row Air Conditioning Unit IDC Cooling System 4 Floor Standing In Row Air Conditioning Unit IDC Cooling System 5

 

Technical Parameter                        

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                           

Floor Standing In Row Air Conditioning Unit IDC Cooling System 6

 

Factory  Details                                                

 

Precision Air Conditioning Unit In Row For Modular Data Center 6

Delivery & Packing                                           

Floor Standing In Row Air Conditioning Unit IDC Cooling System 8

 

Cases                                                       

Floor Standing In Row Air Conditioning Unit IDC Cooling System 9

 

 

 

 

 