Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > In Row Air Conditioning Unit > Floor Standing In Row Air Conditioning Unit IDC Cooling System

Floor Standing In Row Air Conditioning Unit IDC Cooling System

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CR040A, CR012A

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

CE In Row Air Conditioning Unit

,

Floor Standing In Row Air Conditioning Unit

,

20kw data center air conditioner

Cooling Capacity:
20-50KW
Condition:
New
Mounting:
Floor Standing
Type:
Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Product Name:
IDC Cooling System
Refrigerant:
R410A
Application:
IDC, Data Center , Computer Room
Color:
Black/Grey White/other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
20-50KW
Condition:
New
Mounting:
Floor Standing
Type:
Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Product Name:
IDC Cooling System
Refrigerant:
R410A
Application:
IDC, Data Center , Computer Room
Color:
Black/Grey White/other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Floor Standing In Row Air Conditioning Unit IDC Cooling System

Floor Standing In Row Air Conditioning Unit IDC Cooling System

 

Product Introduction                              

Close-coupled cooling, row-oriented architecture, and in-row cooling are some common names used to describe row-based cooling in data centers. Throughout this paper the term row cooler1 will be used to describe this architecture. In addition, the term “pod” will be used to describe how row coolers are typically deployed (see side bar for definition).

 

 

 

Application                                       

  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction
Floor Standing In Row Air Conditioning Unit IDC Cooling System 0

Floor Standing In Row Air Conditioning Unit IDC Cooling System 1

Advantages and Features                       

Floor Standing In Row Air Conditioning Unit IDC Cooling System 2

High efficiency- EVO intelligent control system

  • Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.

High Efficiency-DC Inverter Compressor of DX System

  • Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

High Efficiency-Backward Centrifugal EC Fan

  • Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;
  • Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;
  • Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;
  • Soft start function, low starting current; Easy maintenance design.

High Efficiency-Electronic Expansion Valve

  • Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;
  • Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;
  • Fast response speed, realizing precise refrigeration.

 

Floor Standing In Row Air Conditioning Unit IDC Cooling System 3

Air Supply Method                               

Floor Standing In Row Air Conditioning Unit IDC Cooling System 4 Floor Standing In Row Air Conditioning Unit IDC Cooling System 5

 

Technical Parameter                        

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                           

Floor Standing In Row Air Conditioning Unit IDC Cooling System 6

 

Factory  Details                                                

 

Precision Air Conditioning Unit In Row For Modular Data Center 6

Delivery & Packing                                           

Floor Standing In Row Air Conditioning Unit IDC Cooling System 8

 

Cases                                                       

Floor Standing In Row Air Conditioning Unit IDC Cooling System 9