Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > In Row Air Conditioning Unit > In Row Cooling Data Room Air Conditioning Unit 40kW

In Row Cooling Data Room Air Conditioning Unit 40kW

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CYA,M08,CR012

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

40kW data room air conditioning

,

data room air conditioning Unit

,

40000W in row air conditioning

Cooling Capacity:
20-50KW
Condition:
New
Mounting:
Floor Standing
Type:
In Row Cooling
Product Name:
Inrow Precision Air Conditioning
Refrigerant:
R410A
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Grey
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
20-50KW
Condition:
New
Mounting:
Floor Standing
Type:
In Row Cooling
Product Name:
Inrow Precision Air Conditioning
Refrigerant:
R410A
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Grey
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
In Row Cooling Data Room Air Conditioning Unit 40kW

Data Room Precision Air Conditioning Unit In Row Cooling Solution 40kw

 

Product Introduction                                   

Inrow cooling precisely cools and conditions air in close proximity and is targeted cooling at the banks of server cabinets that fill the data center. They can be installed on the floor or suspended from overhead making them closer to the actual rack. This setup offers both capacity and efficiency gains. Neither cool air nor warm exhaust air has far to travel, allowing the units to dissipate high heat loads quicker and allows a more scalable approach to cooling your data center.

 

Feature & Benefits                                     

Cooling on demand

  • DC frequency conversion, 10%-100% refrigeration capacity stepless adjustment, high efficiency at part load;
  • High-efficiency EC fan, close to the rack to supply air, the fan can save 20%-30%;
  • The outdoor fan frequency conversion speed regulation, control the air volume according to the demand;
  • Stable dehumidification under a load as low as 10%, excellent performance

 

Safe and reliable

  • The start-up current is small, which can reduce the impact on the power grid;
  • Expert self-diagnosis and fault warning function to ensure operation;
  • Fan N+1 redundant configuration, to avoid equipment operation obstacles caused by unexpected situations;
  • Dual power input, safer and more reliable
In Row Cooling Data Room Air Conditioning Unit 40kW 0

Scope of Applications                         

In Row Cooling Data Room Air Conditioning Unit 40kW 1
  • Mobile base station
  • Outdoor rooms
  • Satellite ground station
  • Paging machine room
  • Network management center
  • Small computer room
  • Small laboratory
  • Wine cellar

 

Air Supply Method                               

In Row Cooling Data Room Air Conditioning Unit 40kW 2 In Row Cooling Data Room Air Conditioning Unit 40kW 3  

 

Technical Parameter                                     

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                          

In Row Cooling Data Room Air Conditioning Unit 40kW 4

 

Factory Details                                                

In Row Cooling Data Room Air Conditioning Unit 40kW 5

 

Packing and Delivery                                         

In Row Cooling Data Room Air Conditioning Unit 40kW 6

 

Cases                                                               

In Row Cooling Data Room Air Conditioning Unit 40kW 7