Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > In Row Air Conditioning Unit > Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CR040

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

R410A data center air conditioning system

,

Black data center air conditioning system

,

2000m3/h in rack cooling systems

Cooling Capacity:
12kw, 25kw, 40kw
Condition:
New
Mounting:
Floor Standing
Type:
InRow Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Product Name:
InRow Airconditioning Unit
Refrigerant:
R410A
Application:
Data Center, IT Room , Computer Room, Cold/hot Aisle
Color:
Black/Grey
Fan Type:
EC Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
12kw, 25kw, 40kw
Condition:
New
Mounting:
Floor Standing
Type:
InRow Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Product Name:
InRow Airconditioning Unit
Refrigerant:
R410A
Application:
Data Center, IT Room , Computer Room, Cold/hot Aisle
Color:
Black/Grey
Fan Type:
EC Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~50000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers

 

Product Introduction                                 

CoolRow is a in-row cooling solution commonly used in data centers requring higher density cooling with greater efficiency and capacity. The unit is placed beteween the servers in a row for offering cooling close to the heat load, the horizontal airflow pattern supports hot aisles and cold aisles configeration. CoolRow improves the efficiency of the overall cooling systems and ensures the steady room temperature for precise operation.

 

Feature & Benefits                                  

Energy Efficiency

Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series

Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

Cold aisle/Hot ailse containment avoids mixing of cold and hot air

 

High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 0
Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 1

Application Range

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 2
  • Cold Aisle/Hot Aisle Application
  • Modularized Data Center Application
  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction

 

Air Supply Method                                                                 

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 3 

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 4

 

Technical Parameter                     

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                                            

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 5

 

Factory Details                                           

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 6

 

Packing & Delivery                                    

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 7

 

Case                                             

Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers 8