Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: R24
Payment & Shipping Terms
Minimum Order Quantity: 1set
Price: 1800-30000USD
Packaging Details: Packed in plywooden case, standard export package
Delivery Time: 10-25 working days
Payment Terms: T/T, L/C
Supply Ability: 300 PCS PER MONTG
Type: |
Modular Data Center |
Mounting: |
Floor Standing |
Application: |
Data Center, Supercomputer Centers, Education, Medical And Other Industries |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year |
Cooling Type: |
Precision In Row Air Conditioning |
Cooling Capacity: |
20-40KW Per Unit |
Color: |
Black/Grey White/other Custom Colors |
Power Distribution System: |
80-300KVA Modular Ups |
Rack Quantity: |
Customized |
Type: |
Modular Data Center |
Mounting: |
Floor Standing |
Application: |
Data Center, Supercomputer Centers, Education, Medical And Other Industries |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year |
Cooling Type: |
Precision In Row Air Conditioning |
Cooling Capacity: |
20-40KW Per Unit |
Color: |
Black/Grey White/other Custom Colors |
Power Distribution System: |
80-300KVA Modular Ups |
Rack Quantity: |
Customized |
3KW Per Rack Modular Data Centers Integrated Modular UPS And Precision In Row Air Conditioning
Product Introduction The Modular data center is designed according to the principles of high efficiency, energy saving, and optimized management. It includes cooling modules, power supply and distribution modules, as well as modules for network, wiring, monitoring, and fire fighting. it has external power supply interfaces, cooling interfaces, network interfaces, and The integrated wiring interface is reserved for the overhead weak and strong current tanks, and the In Row air conditioner is used for cooling, which achieves a high sensible heat ratio of 100%, effectively reducing the overall humidification and dehumidification energy consumption of the data center, and the In Row air conditioner circulates airflow The road is the shortest, increasing the heat density of the data center under the premise of effective cooling, and realizing the energy-saving cooling of the data center.
Benefits
|
Features
• Quickly deploy
Integrated design, factory prefabricated installation, engineering products
Site decoration requirements are low, easy to install, plug and play, greatly shorten the installation time;
Modular design, with the business development on-demand expansion, to further shorten the business on-line time.
• Energy efficient
Sealed channel design, compared to open design, effectively prevent the mixing of hot and cold air, energy saving effect is remarkable;
Using row-level air conditioning refrigeration, heat source near-end refrigeration, to further reduce the cooling loss;
Using efficient modular UPS, you can achieve flexible configuration, can be expanded on demand.
• Intelligent managemen
Perfect alarm platform, support SMS voice alarm, local sound and light alarm, mobile side alatm, really 7 × 24 hours unattended;
Powerful reporting function, the regular state of the engine room for statistical analysis, effectively improve the operation and maintenance capabilities.
• Safe and reliable
Channel top skylight support fire flip linkage, easy to external fire gas into the channel fire;
Critical power supply, refrigeration equipment, redundant design, to ensure business uninterrupted operation;
|
Air Supply Method
Main Basic Unit Introduction
Rack Multi-functional cabinet developed for large, medium and small data centers. It has the advantages of sturdy structure, strong load-bearing capacity, noble and elegant and assembling structure design. Cabinet integrated three major solutions (power management solution, cable management solution, heat dissipation management solution), It can be used as a modular equipment installation infrastructure, cabinet-type power distribution cabinet, rackmounted battery box, Cabinet integrated user equipment, power distribution, UPS, battery box, and monitoring system, greatly save the equipment area in the computer room. Aisle Containment -Modular design Power Supply- Modular UPS According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power. Cooling System - In Row Air Conditioning Unit Inverter In Row air conditioners are tailor-made high-density cabinets, adopts advanced frequency conversion technology and uses the environmentally friendly refrigerant R410A. The output cooling capacity is adjusted in real time according to the change of the detected load, to avoid frequent start and stop, and to ensure the temperature of the computer room environment. Monitoring System The monitoring system system has the characteristics of simple configuration, strong access, and high reliability. It can manage all power, environment, and cooling in data center, integrate mainstream brand access control, video and other security systems, through distributed collection, high concurrent processing capabilities Meet the needs of networked monitoring and management of multiple computer rooms, allowing data center operation and maintenance personnel to control the operation safety of the computer room in real time. |
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |