Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: CYAT40D/U
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Cooling Capacity: |
26kW-120kW |
Mounting: |
Floor Standing |
Type: |
Precision Air Conditioning Unit( Air Cooled ) |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Product Name: |
Computer Room Air Conditioning |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey White/other Custom Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
2000~50000m3/h |
Voltage: |
380v/220v,220V/380V,380V/415V |
Cooling Capacity: |
26kW-120kW |
Mounting: |
Floor Standing |
Type: |
Precision Air Conditioning Unit( Air Cooled ) |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Product Name: |
Computer Room Air Conditioning |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey White/other Custom Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
2000~50000m3/h |
Voltage: |
380v/220v,220V/380V,380V/415V |
Server Computer Room Air Conditioner Data Center IDC Cooling System Data Center Cooling Unit
Product Introduction With the improvement of electricall equipment integration degree, equipment unit volurme power densityincrease, also more and more strict control of the indoor temperature, room temperature control equip-ment to ensure good indoor ernvironment is becoming more and more important to the equipment room dedlicated Vrcoolertech brand cooling air conditioning units,24"365 full-year refrigeration,effectivelyreduce the indoor termperature, and can consider introducing outdoor air to replace the wind, reduce therefrigeration system on time, according to the setting of indoor temperature and outdioor natural tempera-ture difference between air section.
Applications Computer room and data center Switch room and mobile center station in telecommunication High-tech environment and lab Industrial automation control room and precision manufacturing workshop Standard test room and calibration center UPS and battery room Test room in hospital Biochemical culture chamber
|
Air Supply Method
Technical Features
High reliability Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition. All-day running design can guarantee the main equipment safe operation. All parts had passed severe test and confirmed stable and reliable before delivery. High energy efficiency Sensible heat ratio is up to 91%. Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25. The optimal and high efficiency compressor and fans. “W/M” type evaporator with super large heat exchange area. Independent air duct design can reduce air resistance significantly and minimize fans power. Variable frequency design on ODU is more efficient and has longer working life. Advanced control logic can effectively avoid competitive running and output cooling capacity according to actual cooling capacity demand. Easy maintenance Front panel maintenance: All maintenance work can be operated from front panel. Air filter with metal frame: Cleanable repeatedly, low maintenance cost Self-cleaning humidifier: lower maintenance work Modular design with least spare parts Pressure difference monitoring for air filters can detect whether air filters was blocked or not. Multiple types Wide capacity range: air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW). Multiple cooling mode: air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling. Multiple air supplying modes: cap tuyere mode, air duct mode, floorboard mode. Multiple refrigerant types: R410A, R407C, R22. Wide ambient air temperature rang: standard range(-20℃~50℃),low temperature range(-40℃~50℃). |
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |