Data Room Precision Air Conditioning Units Server Cabinet Cooling

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYAT40D/U

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

R407C Precision Air Conditioning Units

,

ISO Precision Air Conditioning Units

,

70KW server cabinet air conditioning

Cooling Capacity:
70KW
Mounting:
Floor Standing
Condition:
New
Type:
Chilled Water Unit
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Product Name:
Close Control Unit
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey White/other Custom Colors
Airflow:
Upflow Down Reture
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
70KW
Mounting:
Floor Standing
Condition:
New
Type:
Chilled Water Unit
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Product Name:
Close Control Unit
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey White/other Custom Colors
Airflow:
Upflow Down Reture
Voltage:
380v/220v,220V/380V,380V/415V
Data Room Precision Air Conditioning Units Server Cabinet Cooling

Precision Air Conditioning Data Room Server Cabinet  Cooling 

 

Products Introduction                                      

CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.

 

Benefits                                      

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 0
Data Room Precision Air Conditioning Units  Server Cabinet Cooling 1

Features                                  

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 2

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.

 

Applications                                           

 

„ Computer room and data center

„ Switch room and mobile center station in telecommunication

„ High-tech environment and lab

„ Industrial automation control room and precision manufacturing workshop

„ Standard test room and calibration center

„ UPS and battery room

„ Test room in hospital

„ Biochemical culture chamber

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 3

 

Technical Parameters                                 

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                              

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 4

 

Factory Details                                     

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 5

 

Packing & Delivery                                      

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 6

 

Case                                         

Data Room Precision Air Conditioning Units  Server Cabinet Cooling 7