Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw

Basic Information
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: CYAT40D/U
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Detail Information
Cooling Capacity: 40KW Mounting: Floor Standing
Type: Precision Air Conditioning Unit( Air Cooled ) Operating Voltage: 380/400 VAC,230 VAC,220V
Product Name: Close Control Unit Refrigerant: R22(R407C/R410A)
Application: Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity Color: Black/Grey /other Custom Colors
Power: 3N-380V-50Hz,220v/50hz/60hz Airflow: 2000~50000 M3/h
High Light:

CCU server room air conditioning units

,

40KW server room air conditioning units

,

ccu server room aircon


Product Description

Close Control Unit Control CCU Server Room Air Conditioning 26-120KW

 

Products Introduction                                    

CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.

 

Feature & Benefits                                    

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 0

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 1

Air Supply Method                                                         

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 2

Application Range                                     

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 3
  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Parameters                                      

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                                   

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 4

 

Factory Details                                        

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 5

 

Packing & Delivery                                        

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 6

 

Case                                                       

Close Control Unit Control CCU Server Room Air Conditioning 26-120 kw 7

 

 

 

 

 

Contact Details
Janet

WhatsApp : +8618326091011