Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE ISO
Model Number: MDC
Payment & Shipping Terms
Minimum Order Quantity: 1PCS
Price: USD3000-10000/pcs
Packaging Details: Standard export package
Delivery Time: 20-35 days
Payment Terms: L/C, T/T
Supply Ability: 200 SETS PER MONTH
Application: |
Network Closets Or Telecom Sites , Edge Of Network |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet Quatities: |
Single Cabinet |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Application: |
Network Closets Or Telecom Sites , Edge Of Network |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet Quatities: |
Single Cabinet |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Micro Data Centers Provide An All-In-One Solution Combining Power, Cooling, Monitoring, And Racks
Product Introduction
Coolnet Micro data centers provide an one-stop solution with combining power, cooling, monitoring, and racks that are built for unique expectations and constraints. Its compact and flexible design make it ideal for deployment at the edge of the network, network closets or telecom sites. As a result, these solutions have high flexibility which enables customers to scale up or down depending on their requirements. |
1.All-in-one: Integrated Rack, Air conditioner, UPS, PDU, Monitoring, site management etc. 2.Rapid deployment: Plug in and play without engineering survey 3.Intelligent, visual, and cloud management 4.Accurately refrigerated, energy-saving and highly efficient 5.Modularization: UPS + Battery, can be expanded if necessary |
Advantages
Simple: It is prefabricated, pre-installed, and pre-tested; on-site installation only takes two hours; SMS alarm, remote web platform monitoring, and centralized management for multiple data centers to provide unattended operation; remote charge and discharge battery function simplifies Available:The reliable UPS power supply and distribution system continuously escorts IT equipment, and can also customize a highly reliable system architecture that meets the national standard A and B standards to meet the availability requirements of different users. Area saving: integrated design, covering an area of more than 40% less than traditional construction mode; Saving supporting investment: fully enclosed design, can be installed in various environments (computer room, utility room, office, etc.), without special investment in the construction of computer room and supporting facilities. |
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |