Product Name: |
Cabinet System |
Refrigerant: |
R134a,R407C,R22(R407C/R410A),R410A |
Application: |
Network Closets Or Telecom Sites , Edge Of Network |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
UPS Type: |
Online ,Rack Mounted Type |
Product Name: |
Cabinet System |
Refrigerant: |
R134a,R407C,R22(R407C/R410A),R410A |
Application: |
Network Closets Or Telecom Sites , Edge Of Network |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
UPS Type: |
Online ,Rack Mounted Type |
Small-Scale Modular Data Center Architecture Micro Data Center (MDC) Designed For Computer Workloads
Product Introduction
Relying on the rich experience in the data center, we launch cabinet-level micro data center solutionsn, and integrate UPS power supply and distribution,Cooling, cabinets, wiring, monitoring and fire protection systems. providing safe, reliable and efficient operation support for IT equipment, realize one-stop deployment and unified operation and maintenance management of the data room, and create a cabinet-based micro data center.
Benefits
|
Features
1.Hihg intergrated: Integrated Rack, Air conditioner, UPS, PDU, Monitoring, site management etc. 2.Rapid deployment: Plug in and play without engineering survey 3.Intelligent, visual, and cloud management 4.Accurately refrigerated, energy-saving and highly efficient 5.Modularization: UPS + Battery, can be expanded if necessary 6.Reliable: Air conditioners can automatically start when power is supplied, eliminating the risk of overheat. Batteries can intelligently power off if overheating, preventing fires 7.Efficient: The rack-level data center only occupies 0.5m2 footprint, and saves space by at least 50% |
Advantages
1. Simpler Integrated design, integrate UPS, battery, power distribution, air conditioning, monitoring, wiring, fire protection and other products in the cabinet, get rid of the traditional sub-construction mode; modular design, unified interface of each component.
2. Faster Carrying out the product design of the traditional project, saving the time of preliminary project design and on-site installation, and completing all the installation projects within one day, which is more than 2 times faster than the traditional construction mode.
3. More intelligent Coolnet can realize 365 days 7X24 hours unattended, remote monitoring and intelligent humanized management. Minimize IT deployment and operation and maintenance costs.
The biggest advantage of the mini-intelligent computer room is enclosed and dust-proof. The internal air of the computer room can reach the air cleanliness standard of the A-level computer room, the failure rate of IT equipment is greatly reduced, and the life cycle is extended by 1 to 2 times.
Noise test case: Place 4 rack-mounted servers, 2 switches and other equipment in a common cabinet, and the test room noise is about 75dB; The same IT equipment is placed in the MICROOM, the test noise is reduced to about 50dB, the noise intensity is reduced by 25 dB, and the noise reduction is about 85%. |
Structure
Cooling System
1. 3.5-10.5KW cooling capacity, accuracy ±0.5℃ 2.Inverter compressor + double EC fan, PUE≤1.4 3. Low load anti-condensation technology 4.N+X redundant group control
1. 3-30KVA capacity optional 2. Rack mount
|
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |