Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Electrical Cabinet Air Conditioner > Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner

Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: CJK400-600MQ

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: $400.00-5000.00/set

Packaging Details: Packed in plywooden case and CTN

Delivery Time: 20-35working days

Payment Terms: T/T

Get Best Price
Highlight:

800W Electrical Cabinet Air Conditioner

,

ISO14001 Electrical Cabinet Air Conditioner

,

Door Mounted 800W air conditioner

Supply Ability:
3000 Unit/Units Per Month
Color:
Black/Grey White/other Custom Colors
Mounting:
Door Mounted
Power:
1N-220V-50Hz,110v/50hz/60hz,48V
Application:
Telecom Sites, Base Station
Type:
Cabinet Air Conditioner
Airflow:
300m³/h
Core Components:
Compressor, Condenser, Evaporator, Fans
Operating Voltage::
220V, 50/60Hz
Certificate:
Ce, ISO9001, ISO14001, CE
Supply Ability:
3000 Unit/Units Per Month
Color:
Black/Grey White/other Custom Colors
Mounting:
Door Mounted
Power:
1N-220V-50Hz,110v/50hz/60hz,48V
Application:
Telecom Sites, Base Station
Type:
Cabinet Air Conditioner
Airflow:
300m³/h
Core Components:
Compressor, Condenser, Evaporator, Fans
Operating Voltage::
220V, 50/60Hz
Certificate:
Ce, ISO9001, ISO14001, CE
Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner

Powered Cabinet Air Conditioner 800w For Telecom Control Cabinet

 

Product Introduction                                            

Coolnet EA series air conditioner has short air duct, well distributed airflow and close loop cooling design. The protective cover is integrated, thus no air conditioner cover is needed on cabinet.
The benefits result from using cabinet air conditioner is greater operating efficiency, lower power consumption and longer life for heat sensitive equipment.
Besides this, we also have AC 300w to 5000w, DC 300w to 5000w cabinet air conditioner , Cabinet Heat Exchanger, Peltier Air Conditioner, etc. If you need other item, please contact us.
 
 
 
Benefits                                                                   
Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner 0
Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner 1
 
Advantages                                                                       
Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner 2

The EA 300 is a compact, high efficient hybrid air conditioner with heat exchanger.

The design is optimized for applications with limited space available, but where functionality and performance still cannot be compromised.

Ø 220VAC for air conditioner, -48VDC for heat exchanger

Ø 3000W cooling capacity @L35L35

Ø 120w/k heat exchanger

Ø Compact design

Ø Door mounted – easy integration in outdoor cabinets and enclosures

Ø Wide working temperature range: -40ºC to +55 ºC

Ø Air conditioner and heat exchanger system as backup

Ø Energy saving, different cooling mode for varied ambient conditions

Ø Low noise, the noise level of unit can be reduced according to the heat load, silently operating in most time

Ø Lifetime >10 years – minimum maintenance

Ø Environmental friendly – R134a and RoHS compliant

Ø IP55 and Corrosion Proof

Ø Dedicated design by delay start

Ø RS485 for remote control

 

Application                                                                

The Cabinet air conditioner has a wide range of applications, widely used in communications, power, finance, energy, transportation, environmental protection, machinery industry and other fields. Telecom Electrical Cabinet Air Conditioner , 800W Air Conditioner 3

 

Technical Specification                                            

Model   EA-300
Power Supply( V,Hz)   1P 220,50
Dimension (mm) W 286
H 445
D 175
Cooling Capacity   300W
Running Current   1.48A
Starting Current   6.5A
Power   287W
Refrigerant Type   R134a
Noise Level   55dB
Cabinet Protection Ration internal circuit IP34
external circuit IP33
Cabinet Temperature Limits   25℃~38℃(Factory Set 30℃)
Ambient Temperature Limits   -5℃~43℃
Power Connection   Triangle Power Plug( 2 Meters Length)
Weight   15Kg
Color   RAL 7035(Light Gray)
Flow Rate internal circuit 70m3/h
external circuit 150m3/h
Temperature Control Type   Digital Display

Test condition: dry bulb temperature inside the cabinet 35 ℃, wet bulb temperature 26 ℃;

dry-bulb temperature outside the cabinets 35 ℃

 

Certitication                                                                    