Place of Origin: | CHINA |
---|---|
Brand Name: | COOLNET |
Certification: | CE,ISO |
Model Number: | CYA,M08,CR012 |
Minimum Order Quantity: | 1set |
Price: | 1800-30000USD |
Packaging Details: | Packed in plywooden case, standard export package |
Delivery Time: | 10-25 working days |
Payment Terms: | T/T, L/C |
Supply Ability: | 300 PCS PER MONTG |
Cooling Capacity: | 20-50KW | Condition: | New |
---|---|---|---|
Mounting: | Floor Standing | Type: | InRow Unit |
After-sales Service Provided: | Engineers Available To Service Machinery Overseas | Operating Voltage: | 380/400 VAC,230 VAC,220V |
Warranty: | 1 Year | Product Name: | Inrow Type Precision Air Conditioning |
Refrigerant: | R410A | Application: | Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidityData Center, IT Room |
Color: | Black/Grey White/other Custom Colors | Fan Type: | Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan |
Power: | 3N-380V-50Hz,220v/50hz/60hz | Airflow: | 2000~50000 M3/h |
Voltage: | 380v/220v,220V/380V,380V/415V | ||
High Light: | In Row Air Conditioning Unit 2000m3/H,In Row Precision Air Conditioner,Precision Air Conditioning Unit R410A |
Emerson Computer Room In-Row Precision Air Conditioner With Constant Temperature And Humidity
2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server Room
Product Introduction The in-row air conditioner, also known as the in-row refrigeration unit, is a precision refrigeration system specially designed for high heat density racks. Because the unit is close to the heat source, the base return air temperature and evaporating pressure can be increased.
The cooling efficiency is improved. The unit adopts EC fan and DC inverter EC compressor to make the system achieve high refrigeration efficiency and low air-conditioning energy consumption. It can be equipped with air-cooled and water-cooled.
The three condensation methods of type and chilled water type can be widely used in high heat density computer rooms such as data centers (IDC), modular data centers, and container data centers.
Main Features
|
![]() |
Application
![]() |
|
Advantages
The advantages mainly lie in specific applications, such as modular data centers, which do not have many advantages in ordinary computer rooms.
(1) Near-end refrigeration: Close to the heat source for refrigeration, with the design of hot and cold passages, to further optimize the indoor airflow organization, reduce the overall PUE value of the computer room, and improve the cooling efficiency.
(2) High energy efficiency ratio: high return air temperature and high heat output equipment have a high matching degree, which makes the unit energy efficiency ratio very good, low energy consumption and low operating cost.
(3) High reliability: ultra-long life design, 24 hours and 365 days of uninterrupted operation, the average design life is about 10 years.
(4) Adopt DC inverter compressor:dynamic refrigeration, high efficiency, low consumption, high adaptability; Equipped with EC centrifugal fan, N+1 redundancy design, automatically adjust the air supply volume according to the load of the computer room.
(5) Size:The size of the standard rack is consistent with the appearance of the cabinet, beautiful and easy to expand. |
![]() |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |
Certificates
Factory Details
Packing & Delivery
Cases