Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: XR040
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Cooling Capacity: |
40KW |
Mounting: |
Floor Standing |
Condition: |
New |
Type: |
In Row Air Conditioning |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Power Supply: |
380/400 VAC,230 VAC,220V , 50/60HZ |
Warranty: |
1 Year |
Product Name: |
Row Based Cooling Unit |
Refrigerant: |
R410A |
Application: |
Modularized Data Center, High Heat Density Data Center, Container Data Center |
Cooling Capacity: |
40KW |
Mounting: |
Floor Standing |
Condition: |
New |
Type: |
In Row Air Conditioning |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Power Supply: |
380/400 VAC,230 VAC,220V , 50/60HZ |
Warranty: |
1 Year |
Product Name: |
Row Based Cooling Unit |
Refrigerant: |
R410A |
Application: |
Modularized Data Center, High Heat Density Data Center, Container Data Center |
In Row Air Conditioning Row Based Cooling Unit For High Heat Density Data Center
Product Introduction
Cool Row series In Row air conditioning increase the heat density of the data center and realize the energy saving of the data center. Compared with traditional computer room air conditioners, In Row air conditioning have the characteristics of 100% sensible heat ratio, low fan power consumption, high energy efficiency ratio, low computer room decoration requirements, convenient installation, standardized cabinet design and easy expansion. Features & Advantages
|
||
Applicable Scene
■Local overheating area
■ High heat density data center
■ Modularized data center
■ Container data center
■ Data centers with insufficient floor heights that cannot use down-supply air or pipelines
■The cabinet adopts cold and hot aisle layout |
||
High Efficiency-DC Inverter Compressor of DX System Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability
High Efficiency-Backward Centrifugal EC Fan Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%; Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand; Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation; Soft start function, low starting current; Easy maintenance design
High Efficiency-Electronic Expansion Valve Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving; Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load; Fast response speed, realizing precise refrigeration; |
Structure & Components
|
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |