380V Computer Room Air Conditioners For Telecommunications Exchange Room

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: CYA M15,M30,

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $1000.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

380V Computer Room Air Conditioners

,

Floor Standing Computer Room Air Conditioners

,

380VAC Computer Room Air Conditioning Unit

Name:
Computer Room Air Cooling Units
Product Application:
Computer Room/Industrial Automatic Rooms/ Printing Factory/Offfice,Industrial,Heat Recovery,adjust Cold/heat/humidity
Product Capacity:
10KW-40KW
Operating Voltage:
380VAC,230 VAC
Product Mounting:
Floor Standing
Warranty:
1 Year
Refrigerant:
R407C
Air Flow:
5000-10000m³/h
Name:
Computer Room Air Cooling Units
Product Application:
Computer Room/Industrial Automatic Rooms/ Printing Factory/Offfice,Industrial,Heat Recovery,adjust Cold/heat/humidity
Product Capacity:
10KW-40KW
Operating Voltage:
380VAC,230 VAC
Product Mounting:
Floor Standing
Warranty:
1 Year
Refrigerant:
R407C
Air Flow:
5000-10000m³/h
380V Computer Room Air Conditioners For Telecommunications Exchange Room

380V Computer Room Air Conditioners For Telecommunications Exchange Room

 

Product Introduction                                    

Coolnet power precision air conditioning units are widely used in such special places as telecom, bank, museum, laboratory, wafer fab and hospital operating room where ambient temperature, humidity and clealiness are highly demanding. Cool-smart series have the following features: Fully intelligent and precise control of constant temperature and humidity function, high sensible heat ratio, high energy efficiency refrigeration system design, large air volume, small enthalpy difference design, to meet the professional temperature control needs of the computer room, ultra-wide grid adaptability, phase sequence fault-tolerant wind.

 

 

Applications                                              

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber
380V Computer Room Air Conditioners For Telecommunications Exchange Room 0

 

Structure & Componenets                                   

380V Computer Room Air Conditioners For Telecommunications Exchange Room 1

Comprossor

• Adopt environmentally friendly refrigerant R410A, high performance
• The compressor has strong ability to withstand impurities and liquid shock
• Powerful built-in protection functions, including built-in motor disconnection protection (temperature and current), built-in pressure relief valve, built-in exhaust temperature protection, built-in anti-stop reverse stop valve, etc.
 
 Fan
• Backward centrifugal fan
• Efficient, improve the energy efficiency ratio of the whole machine
• Low noise
• The air volume is more than 35% higher than the air volume of the comfort air conditioner with the same cooling capacity
 
Humidifier
• Direct electrode humidifier
• Fuzzy logic control humidification program
• Removable for cleaning
• Microcomputer-controlled automatic flushing cycle process
• Low noise water supply solenoid valve to ensure quietness
• Automatic failure prevention during operation

 

Technical Parameters

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

 

Certificates                                            

380V Computer Room Air Conditioners For Telecommunications Exchange Room 2

 

Factory Details                                           

380V Computer Room Air Conditioners For Telecommunications Exchange Room 3

 

Packing & Delivery                                                           

 

380V Computer Room Air Conditioners For Telecommunications Exchange Room 4

 

Case                                                     

380V Computer Room Air Conditioners For Telecommunications Exchange Room 5