High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CR, DX012A, DX023A

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Precision Air Conditioning Unit InRow

,

Axial Fan In Row Air Conditioner

Product Name:
In-Row Air Conditioning Units
Mounting:
Floor Standing
Cooling Capacity:
20-40KW
Condition:
New
Type:
Row Based Precision Air Conditioning Unit
Voltage:
380/400 VAC,230 VAC,220V
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Airflow:
2500~8500 M3/h Per Unit
Warranty:
1 Year
Refrigerant:
R410A/ R407C
Application:
Data Center, Server Room,Modular Data Center
Color:
Black,Grey,White And Other Custom Colors
Product Name:
In-Row Air Conditioning Units
Mounting:
Floor Standing
Cooling Capacity:
20-40KW
Condition:
New
Type:
Row Based Precision Air Conditioning Unit
Voltage:
380/400 VAC,230 VAC,220V
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Airflow:
2500~8500 M3/h Per Unit
Warranty:
1 Year
Refrigerant:
R410A/ R407C
Application:
Data Center, Server Room,Modular Data Center
Color:
Black,Grey,White And Other Custom Colors
High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers

High Efficiency Fan In-Row Air Cooling Units For High Heat Density Data Centers

 

Product Introduction                                           

In-row air conditioners are specially designed for modern modular data centers, such as various modular data centers, data centers with low PUE requirements, local hot spots in computer rooms, high heat density areas in medium and large computer rooms, and computer rooms Data center with tight area, etc.


The use of in-row air conditioners in these places is mainly to solve the problem that the hot and cold air flow may be short-circuited, to ensure the uniform temperature of the server cabinets, and to eliminate local hot spots, thereby increasing the operating reliability of the server and effectively reducing unnecessary energy consumption.

 

Cool-Row Typical Applications                           

  • Single row cabinet and closed cold aisle data center

  • Closed cold aisle data center

  • Closed hot aisle data center

  • Medium & Large enterprises

  • Container data center

  • Edge computing

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 0

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 1

Features                                              

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 2

Electronically Commutated Compressor
♦R410A
♦Compressor speed is infinitely variable dependent on the heat load
♦Energy saving under partial-load mode, improving energy efficiency
♦Significant reduce the start/stop frequency of the compressor
♦Improve the system reliability

 

EC Fan
♦Saving 20~30% energy compared to traditional AC motor
♦Soft-startup function, low startup current
♦Adjust rotary speed automatically according to cooling requirements and airflow pressure, and provide airflow as required
♦N+1 redundancy configuration of fans, ensure the airflow in case of any fan fault
♦Easy-maintenance designed

 

Electronic Expansion Valve
♦Adjust the throttle of valve smoothly and combine with the EC compressor to save the energy
♦Wide range of operations, which can help reduce the superheat degree and improve the EER
♦Realize cooling capacity and heat load precise matching
♦Quick response, realize the precise cooling

Advantages                                          

  • It can be cooled close to the heat source, the air flow path is short, and the cooling capacity loss is small;
  • Adapt to high return air temperature, high matching degree with the output air temperature of equipment with large heat generation;
  • Ultra-high energy efficiency ratio, energy saving, and low operating cost;
  • Ultra-high sensible heat ratio, will not cause excessive dehumidification;
  • High reliability, long life design: 24 hours 365 days uninterrupted operation design, the design life is 10 years;
  • Multiple high-efficiency backward-inclined centrifugal direct-connected fans, air volume redundancy design, each fan is designed to operate at the best efficiency point under standard working conditions;
High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 3

Technical Parameter                          

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                                                   

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 4

 

Factory Details                                    

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 5

 

Packing and Delivery                                           

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 6

 

Case                                                  

High Efficiency Fan In Row Air Cooling Units For High Heat Density Data Centers 7