Place of Origin: | CHINA |
---|---|
Brand Name: | COOLNET |
Certification: | CE,ISO |
Model Number: | CR, XR012A, XR023A |
Minimum Order Quantity: | 1set |
Price: | 1800-30000USD |
Packaging Details: | Packed in plywooden case, standard export package |
Delivery Time: | 20-35Days |
Payment Terms: | T/T, L/C |
Supply Ability: | 300 PCS PER MONTG |
Product Name: | In-Row Air Conditioning Units | Application: | Data Center, Modular Data Center,Container Data Center |
---|---|---|---|
Airflow: | 2500~8500 M3/h | Refrigerant: | R410A/ R407C |
Fan Type: | Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan | Color: | Other Colors |
High Light: | 2500M3/H In Row Air Conditioning Unit,Modular Data Center Air Conditioner,40KW Data Center Air Conditioner |
In Row Type Precision Air Conditioning Unit 40KW
Product Introduction The cool row air conditioner is a device placed between the columns of the server cabinet, and the heat source directly dissipates heat. The precision air conditioner in the inter-row room is a type of air conditioner in the room. It is a horizontal air supply unit. Due to the increasing heat dissipation of the server or communication equipment used in the data center, the traditional air conditioning refrigeration method can no longer meet the requirements of the equipment for temperature and humidity. In order to achieve efficient cooling of the equipment and avoid local overheating phenomenon, cold air must be organized into the interior of the equipment for heat dissipation. At this time, the cold and hot channel isolation or closure of the cold and hot channel can effectively control the short circuit of the cold air flow and hot air flow, and reduce the cooling effect.
Feature & Benefits High Flexibility Air-cooled or chilled water-cooled cooling scheme. Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.
High Reliability & Serviceability 24*7 uninterruptible operation design. Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired. Secondary water tray. Draw and push E-box. Hot-swappable fans. Highly safety performance guaranteed by functions and protections designed for the unit. 4 Levels of password protection Service access is via the front or rear of the unit.
|
![]() |
Advantages
![]() |
DC Inverter Compressor of DX System Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability.
Backward Centrifugal EC Fan Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%; Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand; Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation; Soft start function, low starting current; Easy maintenance design.
Electronic Expansion Valve Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving; Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load; Fast response speed, realizing precise refrigeration; |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |
Factory Details
Packing & Delivery
Case