Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > In Row Air Conditioning Unit > In row Type Precision air conditioning Unit 40KW

In row Type Precision air conditioning Unit 40KW

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CR, XR012A, XR023A

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 20-35Days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

2500M3/H In Row Air Conditioning Unit

,

Modular Data Center Air Conditioner

,

40KW Data Center Air Conditioner

Product Name:
In-Row Air Conditioning Units
Application:
Data Center, Modular Data Center,Container Data Center
Airflow:
2500~8500 M3/h
Refrigerant:
R410A/ R407C
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Color:
Other Colors
Product Name:
In-Row Air Conditioning Units
Application:
Data Center, Modular Data Center,Container Data Center
Airflow:
2500~8500 M3/h
Refrigerant:
R410A/ R407C
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Color:
Other Colors
In row Type Precision air conditioning Unit 40KW

In Row Type Precision Air Conditioning Unit 40KW

 

Product Introduction                                            

The cool row air conditioner is a device placed between the columns of the server cabinet, and the heat source directly dissipates heat. The precision air conditioner in the inter-row room is a type of air conditioner in the room. It is a horizontal air supply unit. Due to the increasing heat dissipation of the server or communication equipment used in the data center, the traditional air conditioning refrigeration method can no longer meet the requirements of the equipment for temperature and humidity. In order to achieve efficient cooling of the equipment and avoid local overheating phenomenon, cold air must be organized into the interior of the equipment for heat dissipation. At this time, the cold and hot channel isolation or closure of the cold and hot channel can effectively control the short circuit of the cold air flow and hot air flow, and reduce the cooling effect.

 

Feature & Benefits                                               

High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

 

High Reliability & Serviceability

24*7 uninterruptible operation design.

Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.

Secondary water tray.

Draw and push E-box.

Hot-swappable fans.

Highly safety performance guaranteed by functions and protections designed for the unit.

4 Levels of password protection

Service access is via the front or rear of the unit.

 

In row Type Precision air conditioning Unit 40KW 0

In row Type Precision air conditioning Unit 40KW 1

 

Advantages                                                    

In row Type Precision air conditioning Unit 40KW 2

DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability.

 

Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design.

 

Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Fast response speed, realizing precise refrigeration;

 

Technical Parameter                                     

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

 

Factory Details                                             

In row Type Precision air conditioning Unit 40KW 3

 

Packing & Delivery                            

In row Type Precision air conditioning Unit 40KW 4

 

Case                                                                         