Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: XR060A

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Dynamic Cooling Air Conditioning Cabinets

,

R410A Air Conditioning Cabinets

,

In Row Air Conditioner R410A

Capacity:
40KW
Product Mounting:
Floor Standing
Product Application:
Modularized Data Center, High Heat Density Data Center, Container Data Center
Refrigerant:
R410A
Condition:
New
Type:
In Row Air Cooling Units
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Power Supply:
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty:
1 Year
Name:
Row Based Cooling Unit
Capacity:
40KW
Product Mounting:
Floor Standing
Product Application:
Modularized Data Center, High Heat Density Data Center, Container Data Center
Refrigerant:
R410A
Condition:
New
Type:
In Row Air Cooling Units
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Power Supply:
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty:
1 Year
Name:
Row Based Cooling Unit
Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation

Dynamic Cooling System In-Row Air Conditioner Units For Data Center Heat Dissipation

 

Product Introduction                                               

 

The air-conditioning cabinets and fans of the in-row air conditioners are arranged in a dense arrangement of multiple rows and multiple rows. The characteristics of large air volume, uniform air supply, and good heat exchange effect enhance the cooling effect of the air conditioner and eliminate the problem of local hot spots in the computer room. Cool-row in-row air conditioners are also more energy-efficient, more efficient, and have lower overall noise, which directly improves the problem of high energy consumption and high noise in the computer room.
 

Application                                                                 

 

  • Internet Data center(IDC)
  • Partially overheated computer room
  • High heat density computer room
  • High energy-saving demand room
  • Modular Data Center
  • Containerized data center
Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 0

Structure & Components                                                   

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 1

DC Inverter Compressor

  • Dynamic cooling to adapt to the rapidly changing load of the computer room;
  • Save energy and improve energy efficiency under low load;
  • It can greatly reduce the number of compressor starts and stops, and improve system reliability.

 

Backward Centrifugal EC Fan

  • Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;
  • Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;
  • Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;
  • Soft start function, low starting current.

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 2

Air Supply Method                                

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 3 Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 4

 

Technical Parameter                                       

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                           

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 5

 

Factory Details                                       

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 6

 

Packing & Delivery                                                              

 

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 7

 

Cases                                                      

Dynamic Cooling System In Row Air Conditioner For Data Center Heat Dissipation 8