Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Computer Room Air Conditioning Unit > IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW

IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M15,19,26,30

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $1000.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

IT Rooms CRAC Air Conditioning

,

30KW CRAC Ac Unit

,

Floor Standing CRAC Air Conditioning

Cooling Capcity:
15-30kw
Product Color:
Black/Grey/White/Other Colors
Mounting:
Floor Standing
Voltage:
380/400 VAC,230 VAC,220V
Application:
Computer Room/Printing Factory/Supper Market/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Front Flow
Condition:
New
Cooling Capcity:
15-30kw
Product Color:
Black/Grey/White/Other Colors
Mounting:
Floor Standing
Voltage:
380/400 VAC,230 VAC,220V
Application:
Computer Room/Printing Factory/Supper Market/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Front Flow
Condition:
New
IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW

IT Rooms Dedicated CRAC For Inspection Rooms Test Rooms And Power Rooms 15-30KW

 

 

Product Introduction                                       

Compared with traditional air conditioners, Cool-smart series computer room air conditioners occupy a small area and save space. From the aspect of machine performance, it has higher reliability and higher efficiency, and it can also provide a year-round constant temperature and humidity operating environment for the precision equipment in the computer room. So cool-smart precision air conditioners can be widely used in battery rooms, power rooms, inspection rooms and test rooms for precise environment.

 

 

Technical Features                                          

Reliability

Provide Constant temperature & humidity, cleanness precision environment to ensure the main equipment in good running condition

24-hour running design guarantee main equipment operation safety

All units had passed a severe running test before delivery.

 

Efficiency

Maximum evaporator in CRAC industry ensures the highest heat exchange efficiency.

Optimal CFD air duct design: minimum air duct resistance & minimumfan power

Advanced control logic: avoid competitive running and output cooling capacity

SHR (sensible heat ratio) is larger than 90%(Compressor EER>3.1).

Optimal and high efficiency compressor and fan

Maximum evaporator in CRAC industry ensures the highest heat exchange efficiency.

High efficiency & long working life Inverter IDU

 

Maintenance

Front panel maintenance: all maintenance operation can be finished from the front panel

Auto-clean function: lower maintenance work

Metal frame with marine protection grade: less & durable maintenance work.

All metal fans of ODU & IDU: durable & high end

IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 0

 

Scope of Application                               

 

  • Small-Medium size computer room
  • Communication base
  • Rail road, Army, Broadcast base
  • Power room, substation
  • Monitoring room, Power distribution room, Battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, Precision workshop
  • Archives,Store room, Museum, Wine cellar
IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 1
Structure & Components                                                 
IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 2  

Comprossor

• Adopt environmentally friendly refrigerant R410A, high performance
• The compressor has strong ability to withstand impurities and liquid shock
• Powerful built-in protection functions, including built-in motor disconnection protection (temperature and current), built-in pressure relief valve, built-in exhaust temperature protection, built-in anti-stop reverse stop valve, etc.
 

 

Fan
• Backward centrifugal fan
• Efficient, improve the energy efficiency ratio of the whole machine
• Low noise
• The air volume is more than 35% higher than the air volume of the comfort air conditioner with the same cooling capacity

 

Humidifier
• Direct electrode humidifier
• Fuzzy logic control humidification program
• Removable for cleaning
• Microcomputer-controlled automatic flushing cycle process
• Low noise water supply solenoid valve to ensure quietness
• Automatic failure prevention during operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Parameters                                            

 

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

 

Certificates                                          

IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 3

 

Factory Details                                      

IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 4

 

Delivery & Packing                                                     

IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 5

 

Case                                               

IT Rooms CRAC Air Conditioning For Inspection Rooms Test Rooms 15-30KW 6