Precision Cooling Systems Used In UPS Power Rooms 40-80KW

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYA T45,T51,T55,T80

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Floor Standing Precision Cooling Systems

,

80KW Precision Air Conditioner

,

80KW Precision Cooling Systems

Name:
Precision Cooling Units Air Cooling Systems
Capacity:
40-80kW
Product Voltage:
380v/220v,220V/380V,380V/415V
Refrigerant:
R22(R407C/R410A)
Airflow:
11500-25000 M3/h
Mounting:
Floor Standing
Color:
Black,Grey ,White, Other Colors
Type:
Air Cooled Unit/Water Cooled Unit
Application:
Large Data Center, Large Supermarket,Computer Rooms, Telecommunication Data Centers
Product Function:
Precision Air Conditioning Units
Warranty:
1 Year(12months)
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Name:
Precision Cooling Units Air Cooling Systems
Capacity:
40-80kW
Product Voltage:
380v/220v,220V/380V,380V/415V
Refrigerant:
R22(R407C/R410A)
Airflow:
11500-25000 M3/h
Mounting:
Floor Standing
Color:
Black,Grey ,White, Other Colors
Type:
Air Cooled Unit/Water Cooled Unit
Application:
Large Data Center, Large Supermarket,Computer Rooms, Telecommunication Data Centers
Product Function:
Precision Air Conditioning Units
Warranty:
1 Year(12months)
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Precision Cooling Systems Used In UPS Power Rooms 40-80KW

Precise Cooling Systems Used In UPS Power Rooms And Large Data Centers 40-80KW

 

Product Introduction                 

Coolnet precision air conditioner is mainly designed to meet the special process of precision equipment and the requirements of specific environment. Also known as constant temperature and humidity air conditioner, it is characterized by large air volume and adapts to various changes in heat load. The coolnet precision air conditioner can control the temperature difference range to 0.1 degrees Celsius or even higher. Similarly, this series of precision air conditioners can use a larger circulating air volume to reduce the enthalpy difference under a certain cooling capacity, so usually the unit can only operate at a higher sensible heat ratio. This happens to be suitable for server rooms and data centers placed in a large number of equipment with high requirements for heat dissipation.

 

Benefits                                     

Precision Cooling Systems Used In UPS Power Rooms 40-80KW 0

Precision Cooling Systems Used In UPS Power Rooms 40-80KW 1

                                                                     

Advantages                                         

Precision Cooling Systems Used In UPS Power Rooms 40-80KW 2

 

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

 

Applications                                    

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

 

Precision Cooling Systems Used In UPS Power Rooms 40-80KW 3

 

Main Components                                        

Precision Cooling Systems Used In UPS Power Rooms 40-80KW 4

Expansion Valve

We use famous brands such as Emerson and Danfoss which has excellent product performance, high sensitivity and easy replacement.

 

Humidifier

Electrode humidifier, using tap water, with automatic cleaning function, can quickly generate pure steam, maintenance does not stop.

 

Scroll Compressor

International famous brand compressor, COP value greater than 4.0, equipped with safety devices to ensure high efficiency, low noise and long life of the unit.

 

Indoor Blower Fan

Direct-drive centrifugal fan with backward curved blades has an average life span of 10 years and can achieve continuous operation for 365 days * 24 hours;

Energy-saving EC fan, DC drive, is better than traditional fans in the field of energy saving.

 

Features                                     

 

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

 

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer working life.

 

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether air filters was blocked or not.

 

  Precision Cooling Systems Used In UPS Power Rooms 40-80KW 5                                                                                          

Technical Parameters                            

 

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 