logo
Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > In Row Air Conditioning Unit > Floor Standing Air Cooling System InRow 10-26kw For Data Centers

Floor Standing Air Cooling System InRow 10-26kw For Data Centers

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: XR12-26

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

InRow Data Center Air Conditioner

,

26kw Data Center Air Conditioning System

,

In Row Air Conditioner Floor Standing

Cooling Capacity:
10-26KW
Product Mounting:
Floor Standing
Application:
Modularized Data Center, High Heat Density Data Center, Container Data Center
Refrigerant:
R410A/R407C
Product Condition:
New
Product Type:
In Row Air Cooling Units
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Power:
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty:
1 Year(12months)
Product Name:
Row Based Cooling Unit
Cooling Capacity:
10-26KW
Product Mounting:
Floor Standing
Application:
Modularized Data Center, High Heat Density Data Center, Container Data Center
Refrigerant:
R410A/R407C
Product Condition:
New
Product Type:
In Row Air Cooling Units
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Power:
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty:
1 Year(12months)
Product Name:
Row Based Cooling Unit
Floor Standing Air Cooling System InRow 10-26kw For Data Centers

10-26kw High Efficiency And Energy Saving In-Row Air Cooling System For Data Centers

 

Product Introduction                                      

Coolnet In-row air conditioners are air-conditioning systems based on advantroced R&D technology platform and it's a solution based on high reliability, high flexibility, and low cost throughout life. The product series include Air Cooling (XR012A, XR023A, XR040A), Chilled Water (XR024C, XR066C), etc.. The cooling unit can meet the demand of 40kW and the chilled water unit is from 33.0kW to 70.9kW. The unit has a standardized design, with two widths of 300mm and 600mm, and the standard unit height is 2000mm and 300mm.The depth of the standard unit for wide-column air conditioners is 1000 mm, 1100 mm, 1200 mm; the depth of 600 mm wide-column air conditioners1000mm, 1100mm, 1200mm. The height and depth of the unit can be customized according to the size of the customer cabinet and it can be placed in racks with up to 7 units.

 

Feature & Benefits                            

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 0

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 1

Typical Application Area                                      

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 2
  • Internet Data center(IDC)
  • Locally overheated computer room
  • High heat density computer room
  • High energy saving demand computer room;
  • Modular data center
  • Micro-module data center
  • Containerized data center

Main Advantages                                   

1. Close the hot and cold aisles, place them close to the rack, and coordinate with the airflow distribution of hot air and forward cold air from the back of the rack, close to the heat source design,
Higher cooling efficiency, saving fan power, more energy saving;
2. The DC inverter compressor is configured, and the cooling capacity is adjustable. It can realize low temperature fluctuation under low speed and low energy consumption.
Fast and energy-saving temperature control effect;
3. Control the air volume and cooling output as needed, and cooperate with EC fans, DC inverter compressors and electronic expansion valve solutions to achieve the best cooling
effect and minimum energy consumption;
4. Equipped with high-efficiency backward-inclined centrifugal EC fan, N+1 redundant design, the air volume is automatically adjusted according to the load of the machine room;
Each fan is designed with a margin of about 25% for the same external pressure and air supply volume requirements;
5. The electronic expansion valve adjustment technology is adopted to smoothly adjust the throttle opening. Compared with the traditional thermal expansion valve, it responds faster to DC changes.
The change of the cooling load of the frequency compressor;
6. Optional 18 external temperature and humidity sensors, which can be placed directly on the heating equipment, and adjust the system in real time according to the actual heating conditions of the equipment.
cooling output;
7. Expert-level fault self-diagnosis, after starting the diagnosis mode, all component faults are automatically detected

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 3

 

Technical Parameter                                                     

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                               

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 4

 

Factory Details                                      

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 5

 

Packing and Delivery                                             

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 6

 

Case                                                  

Floor Standing Air Cooling System InRow 10-26kw For Data Centers 7