Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V

Basic Information
Place of Origin: China
Brand Name: Coolnet
Certification: CE/ISO9001
Model Number: M15-M40
Minimum Order Quantity: 1
Price: $1000.00-5000.00/set
Packaging Details: WOODED
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000-5000/set/month
Detail Information
Cooling Capcity: 16-40kw Product Color: Black/Grey/White
Product Mounting: Floor Standing Power Voltage: 380/400 VAC,230 VAC,220V
Application: Computer Room/Supper Market/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity Power: 3N-380V-50Hz,220v/50hz/60hz
Airflow: Front Flow/Down Ward Flow Product Condition: New
High Light:

380V Server Room Ac Unit

,

40KW Server Room Ac Unit

,

Floor Standing Server Room Cooling Units


Product Description

16-40KW 380V High Efficiency And Reliability Multiple Air Supply Server Rooms AC Units

 

 

Product Introduction                               

Compared with traditional air conditioners, Cool-smart series computer room air conditioners occupy a small area and save space. From the aspect of machine performance, it has higher reliability and higher efficiency, and it can also provide a year-round constant temperature and humidity operating environment for the precision equipment in the computer room. So cool-smart precision air conditioners can be widely used in battery rooms, power rooms, inspection rooms and test rooms for precise environment.

 

 

 

Feature & Benefits                              

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 0

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 1

 

Structure & Components                          

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 2

Comprossor

• Adopt environmentally friendly refrigerant R410A, high performance
• The compressor has strong ability to withstand impurities and liquid shock
• Powerful built-in protection functions, including built-in motor disconnection protection (temperature and current), built-in pressure relief valve, built-in exhaust temperature protection, built-in anti-stop reverse stop valve, etc.
 

 

Fan
• Backward centrifugal fan
• Efficient, improve the energy efficiency ratio of the whole machine
• Low noise
• The air volume is more than 35% higher than the air volume of the comfort air conditioner with the same cooling capacity

 

Humidifier
• Direct electrode humidifier
• Fuzzy logic control humidification program
• Removable for cleaning
• Microcomputer-controlled automatic flushing cycle process
• Low noise water supply solenoid valve to ensure quietness
• Automatic failure prevention during operation

Application                        

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber
Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 3

Function Introduction                              

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 4

Control panel
The indoor unit of the Cool-smart series CRAC system is equipped with a controller. The controller uses a 4.3-inch touch screen, with Chinese/English intelligent selection, strong operability, parameter setting through touch screen. The display is used to show the temperature, relative humidity, system operation, setpoints and alarms. Use these selector buttons to adjust cooling/heating or humidification and the alarm control settings are used to operate the system. All control setpoints and alarm setpoints in the system can be set by program. The temperature is displayed in the manner. Setpoints are stored in internal memory and will not be lost even in the event of a power outage.

 

Air supply system
Up air supply system, indoor hot air is sucked in through the return air outlet of the Cool-smart units, and then sent to the air by the fan after passing through the coil cap or duct. The upper air system G4 filter is installed in the return air outlet of the unit.
Downward air supply system, indoor hot air is sucked in through the G4 filter on the upper end of the unit, and then passed to the bottom platethrough the coil by the fan of the unit.

 

Indoor unit parts
Cool-smart series indoor units are equipped with evaporator coils, expansion valves, fans, floor water leak detectors, filter driers, high pressure/low pressure switches, high pressure sensors, and compressors. A heater and humidifier are optional equipment. External input power needs to be equipped with a power switch.
Evaporator coils are constructed of copper tubes and aluminum fins and are designed for the high sensible heat requirements of electronic equipment. The indoor air circulation is completed by a centrifugal fan with a high-efficiency, low-noise, backward-inclined outer rotor, which has been adjusted for dynamic balance before leaving the factory. The fan is built with self-adjusting bearings and permanent grease, so there is no need for separate bearing maintenance during its lifetime.
The compressor is installed in the indoor unit, which is suitable for the all-weather operation of the air conditioner in the communication room, which is more beneficial to the life of the compressor.

 

Technical Parameters                               

 

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

Certificates                                                

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 5

 

Factory Details                                            

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 6

 

Packing & Delivery                                                    

 

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 7

 

Cases                                                      

Multiple Air Supply Floor Standing Server Room AC Unit 16-40KW 380V 8

 

 

 

 

 

 

Contact Details
Janet

WhatsApp : +8618326091011