Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Computer Room Air Conditioning Unit > Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M30-M40

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $1000.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

Air Cooling Units R407C

,

Power Rooms Air Cooling Units

,

30KW Air Cooling Units

Cooling Capcity:
30-36.8kw
Color:
Black/Grey/White
Mounting:
Floor Standing
Voltage:
380/400 VAC,230 VAC,220V
Product Application:
Computer Room/Supper Market/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Front Flow/Down Ward Flow
Condition:
New
Cooling Capcity:
30-36.8kw
Color:
Black/Grey/White
Mounting:
Floor Standing
Voltage:
380/400 VAC,230 VAC,220V
Product Application:
Computer Room/Supper Market/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Front Flow/Down Ward Flow
Condition:
New
Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz

Power Rooms And Substations Dedicated Air Cooling Units R407C 30KW 380V 50Hz

 

 

Product Introduction                       

The Cool-smart series focuses on providing constant temperature and humidity environment for the machine to ensure the efficient operation of the machine throughout the year. And compared with traditional air conditioners, Cool-smart series computer room air conditioners have a small footprint and save space. In terms of machine performance, it has higher reliability and higher efficiency, and can also provide a year-round constant temperature and humidity operating environment for precision equipment in the machine room. It can meet the needs of the computer room for the temperature, humidity and cleanliness of the operating environment.

 

 

 

 

Applications                                         
  • Power room, substation
  • Monitoring room, Power distribution room, Battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, Precision workshop
  • Archives,Store room, Museum, Wine cellar

 

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 0

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 1

 

Function Introduction                                

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 2

Control panel
The indoor unit of the Cool-smart series CRAC system is equipped with a controller. The controller uses a 4.3-inch touch screen, with Chinese/English intelligent selection, strong operability, parameter setting through touch screen. The display is used to show the temperature, relative humidity, system operation, setpoints and alarms. Use these selector buttons to adjust cooling/heating or humidification and the alarm control settings are used to operate the system. All control setpoints and alarm setpoints in the system can be set by program. The temperature is displayed in the manner. Setpoints are stored in internal memory and will not be lost even in the event of a power outage.

 

Air supply system
Up air supply system, indoor hot air is sucked in through the return air outlet of the Cool-smart units, and then sent to the air by the fan after passing through the coil cap or duct. The upper air system G4 filter is installed in the return air outlet of the unit.
Downward air supply system, indoor hot air is sucked in through the G4 filter on the upper end of the unit, and then passed to the bottom platethrough the coil by the fan of the unit.

 

The outdoor unit
The air-cooled outdoor unit is installed outdoors; the outdoor unit includes: condensing coil, axial flow fan and motor, etc.

 

Indoor unit parts
Cool-smart series indoor units are equipped with evaporator coils, expansion valves, fans, floor water leak detectors, filter driers, high pressure/low pressure switches, high pressure sensors, and compressors. A heater and humidifier are optional equipment. External input power needs to be equipped with a power switch.
Evaporator coils are constructed of copper tubes and aluminum fins and are designed for the high sensible heat requirements of electronic equipment. The indoor air circulation is completed by a centrifugal fan with a high-efficiency, low-noise, backward-inclined outer rotor, which has been adjusted for dynamic balance before leaving the factory. The fan is built with self-adjusting bearings and permanent grease, so there is no need for separate bearing maintenance during its lifetime.
The compressor is installed in the indoor unit, which is suitable for the all-weather operation of the air conditioner in the communication room, which is more beneficial to the life of the compressor.

 

Technical Parameters                                       

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

Certificates                                    

 

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 3

Factory Details                               

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 4

 

Packing & Delivery                                

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 5

 

Cases                                               

 

Power Rooms And Substations Air Cooling Units R407C 30KW 380V 50Hz 6