Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: CYAT50-T100
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Cooling Capacity: |
50-102KW |
Mounting: |
Floor Standing Mode |
Condition: |
Brand New |
Type: |
Air Cooled Unit |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Warranty: |
1 Year |
Name: |
IT Room Cooling Units |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/Office/Server Rooms/Printing Factory/Industrial/Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey /White/Other Colors |
Airflow: |
5000~50000 M3/h |
Power Voltage: |
380v/220v,220V/380V,380V/415V |
Cooling Capacity: |
50-102KW |
Mounting: |
Floor Standing Mode |
Condition: |
Brand New |
Type: |
Air Cooled Unit |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Warranty: |
1 Year |
Name: |
IT Room Cooling Units |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/Office/Server Rooms/Printing Factory/Industrial/Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey /White/Other Colors |
Airflow: |
5000~50000 M3/h |
Power Voltage: |
380v/220v,220V/380V,380V/415V |
Precise And Reliable Air Cooling System For Providing Constant Humidity And Temperature
Product Introduction Because most of the electronic equipment in the computer room is in continuous operation and has a long working time, the special air conditioner for the computer room is required to be designed to operate continuously with a large load all the year round, and to maintain a high reliability. Comfort air conditioning is difficult to meet the requirements, especially in winter, the computer room has many heating devices due to its good sealing performance, and the air conditioning unit still needs to work normally. At this time, the general comfort air conditioning is difficult because the outdoor condensation pressure is too low normal work. However, the special air conditioner for the computer room can still ensure the normal operation of the refrigeration cycle through the controllable outdoor condenser.
Benefits |
Applications
|
Technical Features
High reliability Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition. All-day running design can guarantee the main equipment safe operation.
High energy efficiency Sensible heat ratio is up to 91%. Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25. The optimal and high efficiency compressor and fans. “W/M” type evaporator with super large heat exchange area. Independent air duct design can reduce air resistance significantly and minimize fans power. Variable frequency design on ODU is more efficient and has longer working life.
Easy maintenance Front panel maintenance: All maintenance work can be operated from front panel. Air filter with metal frame: Cleanable repeatedly, low maintenance cost Self-cleaning humidifier: lower maintenance work Modular design with least spare parts Pressure difference monitoring for air filters can detect whether air filters was blocked or not. |
|
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Certificates
Factory Details
Packing & Delivery
Case