Space Saving Precision AC Units For High Tech Working Places Cooling

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: CYA T70,T80

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Get Best Price
Highlight:

Space Saving Precision Air Conditioning Units

,

Precision AC Units Floor Standing

,

Space Saving Precision AC Units

Cooling Capacity:
70-102kw
Condition:
New
Mounting:
Floor Standing
Type Of AC:
Precision Air Conditioning Unit(air Cooled/chilled Water) 3ton 5ton 10ton
Warranty:
1 Year
Product Name:
Precision Air Conditioning Units
Precision Air Conditioning:
R22(R407C/R410A)
Application:
Computer Room,data Center, Libraries, Laboratories
Color:
Black/Grey/ White
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Downflow/Upflow
Power Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
70-102kw
Condition:
New
Mounting:
Floor Standing
Type Of AC:
Precision Air Conditioning Unit(air Cooled/chilled Water) 3ton 5ton 10ton
Warranty:
1 Year
Product Name:
Precision Air Conditioning Units
Precision Air Conditioning:
R22(R407C/R410A)
Application:
Computer Room,data Center, Libraries, Laboratories
Color:
Black/Grey/ White
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Downflow/Upflow
Power Voltage:
380v/220v,220V/380V,380V/415V
Space Saving Precision AC Units For High Tech Working Places Cooling

Space Saving Precision AC Units For High Tech Working Places Cooling

 

Product Introduction                                           

In the working environment of precision instruments and equipment, maintaining a constant temperature, cleanliness and humidity of the air is essential to ensure the smooth operation of critical electronic and computer equipment. This requires the installation and use of precision air conditioners in the room. Unlike comfort air conditioners, precision air conditioners must operate 24/7, requiring high reliability and minimal power consumption. In addition, Coolnet precision air conditioners can be configured according to needs, with quiet operation and low noise.

 

Feature & Benefits                                     Space Saving Precision AC Units For High Tech Working Places Cooling 0

Space Saving Precision AC Units For High Tech Working Places Cooling 1

Main Parts                                               

Space Saving Precision AC Units For High Tech Working Places Cooling 2

EC fan
The use of electronically commutated synchronous EC electrodes can save energy by 20% to 30%;
Automatically adjust the fan speed according to cooling demand or wind pressure, and provide air volume on demand;

 

Dual electronic expansion valve
Smoothly adjust the throttle opening, and cooperate with the DC inverter compressor to achieve energy saving;
Wide adjustment range, reduce superheat and improve energy efficiency ratio;

 

 

Application Range                                            

 

               

  • Medium and large switch rooms and mobile computer rooms
  • Computer room and electronic information system room (IDC)
  • High-tech environment and laboratory
  • Industrial control room and precision machining equipment
  • Standard testing room and calibration center
Space Saving Precision AC Units For High Tech Working Places Cooling 3

Advantages                                            

Space Saving Precision AC Units For High Tech Working Places Cooling 4

Multiple air supply
The air supply method of the air-conditioned room depends on the source and distribution characteristics of the heat in the room. According to the dense arrangement of equipment in the computer room, the number of cables and bridges, and the wiring method, the air supply method of the air conditioner is divided into lower delivery, upper return, top feed back, top feed side back, side feed side back.

 

Static pressure box air supply
The air conditioner in the computer room usually does not use pipes, but uses the space at the lower part of the raised floor or the upper part of the ceiling as the return air of the static pressure box. static pressure is equal.

Technical Parameters                               

Model: CYA S20D/U S23D/U S26D/U S28D/U S31D/U S35D/U S40D/U S45D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity KW 20.5 23.5 26.8 28.3 31.5 35.5 40.2 45.6
Sensible KW 18.9 21.6 24.2 26.1 28.9 33.2 37.6 42.2
AEER w/w 3.7 3.6 3.6 3.7 3.7 3.7 3.7 3.6
Air Flow m3/h 6830 7650 7580 8500 9200 9800 10600 12000
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 1 1 1 1 1 1 1 1
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 1 1 1 1 1 1 2 2
Rated current A 2.5 2.5 2.8 3.2 3.5 4.1 4.4 4.9
Rated power W 1050 1100 1200 1300 1320 2000 2150 2400
Reheat Capacity KW 6 6 6 6 9 9 9 9
Reheat Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 5 5 5 13
Rated Current A 6 6 6 6 6 6 6 15
Condensor Model   58 58 80 80 100 120 150 150

 

Certificates                                           

Space Saving Precision AC Units For High Tech Working Places Cooling 5

 

Factory Details                                   

Space Saving Precision AC Units For High Tech Working Places Cooling 6

 

Parking & Delivery                                               

Space Saving Precision AC Units For High Tech Working Places Cooling 7

 

Case                                             

Space Saving Precision AC Units For High Tech Working Places Cooling 8