Optional Air Discharge PAC Systems Data Center Cooling System

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYA T60, T85,T90

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

R22 Precision Units In Air Conditioning

,

23500 M3/H Precision Air Conditioners

Name:
Precision Air Cooling System (PAC)
Capacity:
75-90.5kW
Voltage:
380v/220v,220V/380V,380V/415V
Refrigerant:
R22(R407C,R410A)
Airflow:
12500-23500 M3/h
Mounting:
Floor Standing
Color:
Black/Grey /White/Other Custom Colors
Type:
Air Cooled Unit/Water Cooled Unit/Glycol Cold Unit
Application:
Computer Room,Data Center, Laboratories,Large Supermarket
Function:
Precision Air Conditioning
Warranty:
1 Year(12month)
After-sales Service:
Engineers Available To Service Machinery Overseas
Name:
Precision Air Cooling System (PAC)
Capacity:
75-90.5kW
Voltage:
380v/220v,220V/380V,380V/415V
Refrigerant:
R22(R407C,R410A)
Airflow:
12500-23500 M3/h
Mounting:
Floor Standing
Color:
Black/Grey /White/Other Custom Colors
Type:
Air Cooled Unit/Water Cooled Unit/Glycol Cold Unit
Application:
Computer Room,Data Center, Laboratories,Large Supermarket
Function:
Precision Air Conditioning
Warranty:
1 Year(12month)
After-sales Service:
Engineers Available To Service Machinery Overseas
Optional Air Discharge PAC Systems Data Center Cooling System

Optional Air Discharge PAC Systems Data Center Cooling System

 

 

 

Products Introduction                                 

Coolnet precision air conditioners can be combined with micro processing systems to provide full control of computer rooms and precision equipment workshops, including control of ambient temperature, humidity and air cleanliness in these places. It has a high efficiency air filter, an electrode steam humidifier and an electric heater. The precision air conditioner can control the temperature and relative humidity of the equipment room within plus or minus 1 degree Celsius and 5%, thus greatly improving the life and reliability of the equipment.

 

Feature & Benefits                         

Optional Air Discharge PAC Systems Data Center Cooling System 0

Optional Air Discharge PAC Systems Data Center Cooling System 1

Air Supply Method                                      

Optional Air Discharge PAC Systems Data Center Cooling System 2

Product Inner Details                             

Optional Air Discharge PAC Systems Data Center Cooling System 3

DC inverter compressor
Using R410A environmentally friendly refrigerant, DC frequency conversion, high efficiency and energy saving;
Dynamic cooling to adapt to the rapidly changing heat load of the computer room;
Save energy at low loads, improve energy efficiency, and reduce Opex throughout the life cycle;

 

EC fan

The use of electronically commutated synchronous EC electrodes can save energy by 20% to 30%;

Automatically adjust the fan speed according to cooling demand or wind pressure, and provide air volume on demand;

Soft start function, low starting current;

Dual electronic expansion valve design

Accurate matching of cooling capacity and load;

Fast response speed to achieve precise cooling;

Frequency conversion speed owl condensing fan

Frequency conversion control, high efficiency and energy saving;

Owl fan, low noise;

Technical Parameters                                                                                                                                                       

  
Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 