Home > products > Precision Air Conditioning Units > High Utilization Precision Air Handling Units For Server Rooms Equipment

High Utilization Precision Air Handling Units For Server Rooms Equipment

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: T56,T61,T70,T80,T90

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Precision Air Handling Units Floor Standing

,

High Utilization Precision Ahu

,

Server Room Equipment Precision Ahu

Cooling Capacity:
50-70KW
Mounting:
On Floor Standing
Condition:
Brand New
Type:
Precision Air Conditioning Unit( Air Cooled/water Cooled )
Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month )
Name:
PAC Cooling Unit
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey
Power:
3N-380V-50Hz,220v/50hz/60hz
Cooling Capacity:
50-70KW
Mounting:
On Floor Standing
Condition:
Brand New
Type:
Precision Air Conditioning Unit( Air Cooled/water Cooled )
Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month )
Name:
PAC Cooling Unit
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey
Power:
3N-380V-50Hz,220v/50hz/60hz
High Utilization Precision Air Handling Units For Server Rooms Equipment

High Utilization Precision Air Handling Units For Server Rooms Equipment

 

Product Introduction                                

Coolnet precision air conditioners can precisely control the new energy and performance standards of data centers, server rooms and communication networks, as well as the temperature and humidity of computer rooms with low PUE target requirements, for high reliability, better humidity and temperature settings, and part load efficiency. Ensure the smooth operation of the equipment in the computer room, ensure the service life of the equipment, and reduce the company's maintenance costs.

 

Benefits                                                      

High Utilization Precision Air Handling Units For Server Rooms Equipment 0

High Utilization Precision Air Handling Units For Server Rooms Equipment 1

Applications                                                

High Utilization Precision Air Handling Units For Server Rooms Equipment 2

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Features                                        

Precise and reliable
Careful design, strict laboratory testing and comprehensive quality control ensure the unit has excellent reliability;The unit uses parts of world-renowned brands to ensure the high reliability and service life of the whole machine.
Energy saving and high efficiency

 

Energy saving and high efficiency
Save a lot of energy consumption in a reasonable and feasible way, and make full use of natural resources;
The unit uses a high-efficiency fan and a fully enclosed compressor system to reduce operating costs and always pay attention to energy efficiency.

 

Multiple air supply
The air supply method of the air-conditioned room depends on the source and distribution characteristics of the heat in the room. According to the dense arrangement of equipment in the computer room, the number of cables and bridges, and the wiring method, the air supply method of the air conditioner is divided into lower delivery, upper return, top feed back, top feed side back, side feed side back.

 

Static pressure box air supply
The air conditioner in the computer room usually does not use pipes, but uses the space at the lower part of the raised floor or the upper part of the ceiling as the return air of the static pressure box. static pressure is equal.

 

High Utilization Precision Air Handling Units For Server Rooms Equipment 3

 

 

Technical Parameters                                  

 

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                                          

High Utilization Precision Air Handling Units For Server Rooms Equipment 4

 

Factory Details                                          

High Utilization Precision Air Handling Units For Server Rooms Equipment 5

 

Packing & Delivery                                       

High Utilization Precision Air Handling Units For Server Rooms Equipment 6

 

Case                                           

High Utilization Precision Air Handling Units For Server Rooms Equipment 7