Front Flow CRAC Units Small Enthalpy Difference Cooling System

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M13 M20

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $1000.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

15KW CRAC Units

,

Electric Expansion Value CRAC Units

,

Front Flow CRAC Units

Cooling Capacity:
5-15KW
Color:
Black/Grey/White/Other Custom Colors
Mounting:
Floor Standing Units
Voltage:
380/400 VAC,230 VAC,220V
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Air Flow:
Front Flow/Down Ward Flow
Product:
Precision Air Conditioning Unit/ Data Center Cooling Unit /Computer Room Unit /Close Control Unit
Cooling Capacity:
5-15KW
Color:
Black/Grey/White/Other Custom Colors
Mounting:
Floor Standing Units
Voltage:
380/400 VAC,230 VAC,220V
Application:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Air Flow:
Front Flow/Down Ward Flow
Product:
Precision Air Conditioning Unit/ Data Center Cooling Unit /Computer Room Unit /Close Control Unit
Front Flow CRAC Units Small Enthalpy Difference Cooling System

CRAC Units Standard Electric Expansion Value Small Enthalpy Difference Cooling System

 

Product Introduction                                  

Coolnetpower is one of the professional manufacturers in the refrigeration field. In recent years, the electronic system design of Internet data centers and industrial automation computer rooms is highly complex and compact, and the control requirements for special temperature, humidity, high temperature and other operating environments are very high. However, some companies and enterprises have small computer rooms and large amounts of heat. Using large precision air conditioners to dissipate heat will waste operating costs, and using household air conditioners to dissipate heat will waste energy. In response to this situation, the Cool-smart precision air conditioner newly developed by the Coolnet R&D team has the characteristics of small footprint, small enthalpy difference, large air volume, high reliability and strong energy saving, and has been widely welcomed.

 

 

Technical Features                                                

Air supply system
Up air supply system, indoor hot air is sucked in through the return air outlet of the Cool-smart units, and then sent to the air by the fan after passing through the coil cap or duct. The upper air system G4 filter is installed in the return air outlet of the unit.
Downward air supply system, indoor hot air is sucked in through the G4 filter on the upper end of the unit, and then passed to the bottom platethrough the coil by the fan of the unit.

 

Evapotator
Evaporator coils are constructed of copper tubes and aluminum fins and are designed for the high sensible heat requirements of electronic equipment. The indoor air circulation is completed by a centrifugal fan with a high-efficiency, low-noise, backward-inclined outer rotor, which has been adjusted for dynamic balance before leaving the factory. The fan is built with self-adjusting bearings and permanent grease, so there is no need for separate bearing maintenance during its lifetime.

 

Compressor

The compressor is installed in the indoor unit, which is suitable for the all-weather operation of the air conditioner in the communication room, which is more beneficial to the life of the compressor.

 

Front Flow CRAC Units Small Enthalpy Difference Cooling System 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scope of Application                                              

 

  • IT Equipment Room
  • Small Data Center
  • Industrial Clean Room
  • Constant Temperature and Humidity Process Workshop
  • Laboratory
  • Electric Power Equipment Room
  • Railway Subway Machine Room
  • Base Station and Small Telecom Switch Room
  • Medium&Small Telecom Switch Room
Front Flow CRAC Units Small Enthalpy Difference Cooling System 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Parameter                                                     
Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 