Server Room Precision Air Conditioning Units For Industrial Workplaces

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: CYA T55,T80

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Get Best Price
Highlight:

100kw Precision Ac For Server Room

,

Upflow Server Room Ac Unit

,

R407C Precision Ac For Server Room

Cooling Capacity:
30-100kw
Mounting:
Floor Standing Units
Type:
Precision Air Conditioning Unit(air Cooled/chilled Water)
Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Data Center, Libraries, Laboratories,Large Supermarket
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
7000-50000 M3/h
Cooling Capacity:
30-100kw
Mounting:
Floor Standing Units
Type:
Precision Air Conditioning Unit(air Cooled/chilled Water)
Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Data Center, Libraries, Laboratories,Large Supermarket
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
7000-50000 M3/h
Server Room Precision Air Conditioning Units For Industrial Workplaces

Precise Large Server Room Air-Conditioning Units For High-Tech Industrial Workplaces

 

Product Introduction                               

If the environment of the data room is not suitable, it will have a negative impact on the data processing and storage work, which may cause data operation errors, downtime, and even cause frequent system failures and complete shutdowns. Therefore, choosing high-quality, high-efficiency, and well-branded computer room precision air conditioners to ensure the environment and temperature and humidity of the computer room is an essential part for companies and enterprises that own a data computer room. CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.

 

Feature and Benefits                              

Server Room Precision Air Conditioning Units For Industrial Workplaces 0

Server Room Precision Air Conditioning Units For Industrial Workplaces 1

 

Technical Features                                  

Server Room Precision Air Conditioning Units For Industrial Workplaces 2

 

  • High reliability, high energy saving rate, high adaptability, low cost throughout life
  • The air-conditioning unit adopts a modular design, the compressor and evaporator of a refrigeration system are in the same module, and the transportation and handling module is disassembled.
  • The indoor fans are equipped with EBM/Xerox Bai and other brand EC fans as standard, and the fan system saves more than 30% energy than conventional air conditioning units.
  • The same external pressure requirement. The inner fan can be operated with stepless speed regulation, and the temperature difference between the supply and return air, the temperature of the return air and the temperature of the outlet air can be selected for control.
  • Large area V-shaped evaporator, high air volume, high sensible heat ratio
  • Large humidification capacity, suitable for poor water quality, low maintenance

 

Applications                                       

 
  • IDC, Computer room
  • Network equipment room, Server room,communication equipment room
  • Monitoring room, Power distribution room and battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, High precision workshop
  • Archive, Storage room, Museum, Wine cellar

Server Room Precision Air Conditioning Units For Industrial Workplaces 3

 

Technical Parameters                                        

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                                     

Server Room Precision Air Conditioning Units For Industrial Workplaces 4

 

Factory Details                                    

Server Room Precision Air Conditioning Units For Industrial Workplaces 5

 

Packing & Delivery                                

Server Room Precision Air Conditioning Units For Industrial Workplaces 6

 

Case                                            

Server Room Precision Air Conditioning Units For Industrial Workplaces 7