Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: XR012A, XR040A

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Heat Dissipation In Row Cooling Unit

,

Precise In Row Air Conditioning Unit

,

R22 In Row Cooling Unit

Cooling Capacity:
12kw- 40kw
Condition:
Brand New
Mounting:
Floor Standing Units
Type:
In-Row Air Cooling Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month )
Product Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Data Center, IT Room , Computer Room, Data Center Cold/hot Aisle
Color:
Black/Grey/White/Other Custom Colors
Fan Type:
EC Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~40000 M3/h
Power Supply:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
12kw- 40kw
Condition:
Brand New
Mounting:
Floor Standing Units
Type:
In-Row Air Cooling Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month )
Product Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Data Center, IT Room , Computer Room, Data Center Cold/hot Aisle
Color:
Black/Grey/White/Other Custom Colors
Fan Type:
EC Fan
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~40000 M3/h
Power Supply:
380v/220v,220V/380V,380V/415V
Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Precise Heat Dissipation In-Row Air Cooling Units With Large Volume For Data Centers

 

Product Introduction                              

The determinant air conditioner is a cooling device arranged in the cabinet rack and installed side by side with the server cabinet. When adjusting the temperature of the entire internal space of the computer room, the traditional air conditioner is generally far away from the heat source, the effect is uneven, and the energy consumption is large. The biggest feature of the in-line air conditioner is that it can be close to the heat source and directly dissipate the heat of the heat source. Its heat dissipation efficiency is higher, which is more conducive to energy saving. Therefore, the use of determinant air conditioners for heat dissipation in computer room cabinets has been more and more widely used.

 

Feature & Benefits                            

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 0

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 1

Applicatinon Range                             

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 2
  • Mobile base station
  • Outdoor rooms
  • Satellite ground station
  • Paging machine room
  • Network management center
  • Small computer room
  • Small laboratory
  • Wine cellar

 

Structure & Components                                        

DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

 

Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

 

Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 3

 

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 4 

Technical Parameter                  

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates                                               

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 5

 

Factory Details                                               

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 6

 

Packing and Delivery                                       

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 7

 

Cases                                                                      

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers 8