Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: XR040A

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Floor Standing In Row Cooling Unit

,

40kw In Row Air Conditioning Unit

,

In Row Cooling Unit R410A

Cooling Capacity:
10- 40kw
Condition:
Full New
Mounting:
Floor Standing Units
Type:
In-Row AC Unit
Power:
3N-380V-50Hz,220v/50hz/60hz
Warranty:
1 Year(12 Month With No Artificial Damage)
Name:
InRow Airconditioning Unit
Refrigerant:
R410A
Application:
Data Center, IT Room , Computer Room
Color:
Black/Grey /White/Other Colors
Fan:
Brand EC Fan
Airflow:
2000~30000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
10- 40kw
Condition:
Full New
Mounting:
Floor Standing Units
Type:
In-Row AC Unit
Power:
3N-380V-50Hz,220v/50hz/60hz
Warranty:
1 Year(12 Month With No Artificial Damage)
Name:
InRow Airconditioning Unit
Refrigerant:
R410A
Application:
Data Center, IT Room , Computer Room
Color:
Black/Grey /White/Other Colors
Fan:
Brand EC Fan
Airflow:
2000~30000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A

Optional Cooling Capacity In-Row Air Conditioners For Reducing Heating In Server Rooms

 

Product Introduction                                   

 

CoolRow is an in-row cooling solution commonly used where higher cooling density and higher efficiency and capacity are required, such as in data centers and server rooms. Cool-row air conditioners can be placed between a row of servers to provide cooling close to the heat load, and the horizontal airflow pattern supports both hot aisle and cold aisle configurations. Improves the efficiency of the overall cooling system and ensures a stable room temperature for precise operation.

 

Optional Features                            

  • Electrical heater and humidifier
  • Condensate pump
  • Floor water leakage alarm
  • ATS
Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A 0

Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A 1

Advantages                       

Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A 2

Energy Efficiency

Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series

Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

Cold aisle/Hot ailse containment avoids mixing of cold and hot air

 

High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

High Reliability & Serviceability

24*7 uninterruptible operation design.

Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.

Highly safety performance guaranteed by functions and protections designed for the unit.

4 Levels of password protection

Service access is via the front or rear of the unit.

 

Intelligent Control System

Highest protection against downtime, equipment damage and excess wear and tear.

Touched screen interface offers the full visibility.

AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI, ML and IoT to provide the monitoring and reliability for a more efficient operation of the cooling system.

Technical Parameter                       

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                                 

Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A 3

 

Factory Details                                        

 

Downflow Precision Air Cooling Systems Dedicated With Danfoss Expansion Valve 6

 

Packing & Delivery                                                     

Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A 5

 

Cases                                                      

Optional Cooling In Row Air Conditioning Unit For Server Rooms R410A 6