Automatic DC Inverter PAC System Micro Data Center Rack Mounted

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE ISO

Model Number: EC12,EC20

Payment & Shipping Terms

Minimum Order Quantity: 1PCS

Price: USD3000-10000/PCS

Packaging Details: Standard export package

Delivery Time: 20-35 Working days

Payment Terms: L/C, T/T

Supply Ability: 200 SETS PER MONTH

Get Best Price
Highlight:

PAC System Micro Data Center

,

DC Inverter Micro Data Center

Name:
Cabinet System Units
Refrigerant:
R134a,R407C,R22(R407C/R410A),R410A
Application:
Small Enterprise/Network Closets/Telecom Sites/Edge Of Network
Voltage:
380v/220v,110-220v/50-60Hz,220V/50Hz
Name:
Cabinet System Units
Refrigerant:
R134a,R407C,R22(R407C/R410A),R410A
Application:
Small Enterprise/Network Closets/Telecom Sites/Edge Of Network
Voltage:
380v/220v,110-220v/50-60Hz,220V/50Hz
Automatic DC Inverter PAC System Micro Data Center Rack Mounted

Automatic Controller DC Inverter Rack Mounted PAC System Micro Data Center
 

Product Introduction                                             

The integrated cabinet is Coolnet's solution for the construction of small and micro data centers. The cabinet integrates all subsystems of the data center, including the cabinet system, power supply system, cooling system, integrated wiring system and management system. The layout is compact and can be expanded flexibly. The EC series is a single cabinet product, and the ER series is a multi-cabinet product and all of the products could be customized according to customers' needs. Automatic DC Inverter PAC System Micro Data Center Rack Mounted 0

Automatic DC Inverter PAC System Micro Data Center Rack Mounted 1

Technical Features                                                     

Automatic DC Inverter PAC System Micro Data Center Rack Mounted 2
  1. It should have good technical performance.
  2. The cabinet should have anti-vibration, anti-shock, anti-corrosion, dust-proof, waterproof, radiation-proof and other properties, so as to ensure the stable and reliable operation of the equipment.
  3. It should have good usability and safety protection facilities, which are convenient for operation, installation and maintenance, and can ensure the safety of operators.
  4. It should be easy to manufacture, assemble, debug and package and transport.
  5. It should meet the requirements of standardization, normalization and serialization.

 

Advantages                                                               

1. Simpler
The in-depth integration of integrated products and factory pre-validation tests are more standardized, safe and reliable than on-site construction; the fully sealed design eliminates the harm of outside air, dust and corrosive gases to IT equipment; the dynamic ring monitoring system monitors the infrastructure in an all-round way and gives timely alarms Abnormal situation, safe and worry-free.

2. Smaller footprint
The minimum floor area is only 0.7m2, the closed design has strong environmental adaptability, and does not require decoration, flooring and other supporting projects, which effectively reduces CAPEX. The fully enclosed refrigeration improves the energy efficiency of the whole machine, reduces OPEX, and significantly reduces the total cost of ownership (TCO).

3. Better management
The one-stop after-sales service can deal with various equipment failures in a timely manner, saving time and worry; the standard dynamic monitoring system can be monitored and managed locally and remotely, and multiple outlets can be connected to the upper management platform for unified supervision and diversified support.

4. Integration
The integrated cabinet integrates multiple systems such as UPS power supply, power distribution, refrigeration, access control, cabinets, lighting, fire protection, dynamic environment monitoring, and emergency ventilation, procurement, construction Process.
Automatic DC Inverter PAC System Micro Data Center Rack Mounted 3


Technical Parameter                                               

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 