Name: |
Cabinet Systems |
Refrigerant: |
R134a,R407C,R22(R407C/R410A),R410A |
Application: |
Network Closets, Telecom Sites, Edge Computing |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Cabinet Type: |
26U 42U 65U |
Name: |
Cabinet Systems |
Refrigerant: |
R134a,R407C,R22(R407C/R410A),R410A |
Application: |
Network Closets, Telecom Sites, Edge Computing |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Cabinet Type: |
26U 42U 65U |
Micro Data Center 16U 42U Low Costs Small Footprint For Local Edge Computing
Product Introduction
Micro data centers and edge computing enable businesses to grow. They lower server costs because they don't require massive storage space, and give businesses the option to upgrade or downgrade as needed. This will bring a huge cost difference to the development of the enterprise. Because micro data centers can be pinned internally, they are closer to users, reducing latency. These off-the-shelf data systems are much cheaper than traditional data centers. |
Features
|
Advantages
Reduce costs With micro data centers, businesses don't have to concentrate upfront capital expenditures on traditional server hardware. Compared to enterprise data centers, the operating expenses of micro data centers are much lower. Additionally, the distance between client and server computers reduces the higher power costs associated with transferring computations to centralized data centers.
Local computing Micro data centers reduce the geographic distance between client and server computers. The reduced proximity greatly reduces latency.
Small footprint Compared to large data centers, micro data centers have much lower carbon emissions.
Greater elasticity Traditional data centers are often at risk of service disruption if priority lines are damaged. Even with network redundancy in place, traditional data centers will struggle to compete with the options of micro data centers in the event of a failure. Micro data centers may have dozens of failover strategies.
|
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |