Type: |
All-in-one Data Center Units |
Refrigerant: |
R134a,R407C,R22(R407C/R410A),R410A |
Application: |
Network Closets/ Telecom Sites /Edge Computing |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet Quatities: |
Single Cabinet/Multiple Cabinets |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
UPS Type: |
Rack Mounted Type |
Cooling System: |
DC Inverter Rack Mounted PAC Units |
Type: |
All-in-one Data Center Units |
Refrigerant: |
R134a,R407C,R22(R407C/R410A),R410A |
Application: |
Network Closets/ Telecom Sites /Edge Computing |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet Quatities: |
Single Cabinet/Multiple Cabinets |
Operating Voltage: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
UPS Type: |
Rack Mounted Type |
Cooling System: |
DC Inverter Rack Mounted PAC Units |
Efficient And Low Cost Rack Data Center Sealed Micro Data Center With PDU Systems
Products Introduction
Coolnet Micro Data Center is Coolnet's latest all-in-one solution for data centers. Mainly based on intelligent integrated cabinets, the operation of the entire data center is completed through built-in cabinets, power supply, cooling, monitoring, fire protection, security and other systems. Ideal for edge computing applications to reduce latency and improve network security. In addition, the Coolnet micro data center has the advantages of plug-and-play, independence and overall strength, which can save network costs to a large extent.
Benefits
|
Advantages
Reduce costs With micro data centers, businesses don't have to concentrate upfront capital expenditures on traditional server hardware. Compared to enterprise data centers, the operating expenses of micro data centers are much lower. Additionally, the distance between client and server computers reduces the higher power costs associated with transferring computations to centralized data centers. Local computing Micro data centers reduce the geographic distance between client and server computers. The reduced proximity greatly reduces latency. Small footprint Compared to large data centers, micro data centers have much lower carbon emissions. Greater elasticity Traditional data centers are often at risk of service disruption if priority lines are damaged. Even with network redundancy in place, traditional data centers will struggle to compete with the options of micro data centers in the event of a failure. Micro data centers may have dozens of failover strategies. A flexible infrastructure approach Depending on demand, businesses can choose to scale their data needs up or down. The scalability of a micro data center makes it easy to align with enterprise goals. |
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |