Home > products > In Row Air Conditioning Unit > Server Room Dedicated In Row Air Conditioning Unit Precise

Server Room Dedicated In Row Air Conditioning Unit Precise

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CYA,M08,CR012

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Dedicated In Row Air Conditioning Unit

,

In Row Air Conditioning Unit Precise

,

Precise In Row Cooling Unit

Cooling Capacity:
12kw-40kw
Condition:
New
Mounting:
Floor Standing Units
Type:
In-Row AC Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month With No Artificial Damage)
Product Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Data Center, IT Room , Computer Room, For Cold/hot Aisle
Color:
Black/Grey/White/Other Custom Colors
Fan Type:
EC Fans
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~20000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
12kw-40kw
Condition:
New
Mounting:
Floor Standing Units
Type:
In-Row AC Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month With No Artificial Damage)
Product Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Data Center, IT Room , Computer Room, For Cold/hot Aisle
Color:
Black/Grey/White/Other Custom Colors
Fan Type:
EC Fans
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
2000~20000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Server Room Dedicated In Row Air Conditioning Unit Precise

Server Room Large Exchange Rooms Dedicated In-Row Precise Air Cooling Systems

 

Product Introduction                                 

 

Coolnet DX series in-row air conditioners are air conditioners developed for the cooling of server racks in small, medium and large communication data centers. It is especially suitable for micro-module systems with closed hot and cold aisles. The Coolnet DX series features a row-oriented cooling architecture, with each CRAC unit dedicated to cooling a row of server racks. CRAC units can be installed between racks, overhead, or under the floor. Airflow paths are shorter and more clearly defined than room-based cooling. This reduces the required CRAC fan power, increasing efficiency. The row-oriented design also allows cooling capacity and redundancy to be tailored to the actual needs of a particular row, maximizing smooth server operation.

 

Feature and Benefits                        

Server Room Dedicated In Row Air Conditioning Unit Precise 0

Server Room Dedicated In Row Air Conditioning Unit Precise 1

Application                             

  • Large, medium and small exchange room and data center
  • Paging machine room and communication machine room
  • Microwave and satellite ground station
  • Field base stations and mobile telecommunications
  • Network management center and small computer room
  • UPS power room and battery room
  • CT and MRI room
  • Biochemical Incubation Room
  • Standardize testing rooms and calibration centers
  • Precision workshop and dust-free workshop
Server Room Dedicated In Row Air Conditioning Unit Precise 2

 

Structure & Componenets                              

Server Room Dedicated In Row Air Conditioning Unit Precise 3

EVO intelligent control system

Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.;

 

DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

 

Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Server Room Dedicated In Row Air Conditioning Unit Precise 4

 

Technical Parameter                        

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 