Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: CYAT60 T65 T70 T80
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Cooling Capacity: |
60-80KW |
Warranty: |
1 Year(12 Month With No Artificial Damage) |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Mounting: |
Floor Standing Units |
Condition: |
Brand New |
Type Of Air Supply: |
Chilled Water/Air Cooled Units/Water Cooled |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Product Name: |
Data Center Precision Air Cooling Units(PAC) |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/Printing Factory/Cinema/Supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Blue/Black/Grey/other Custom Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
15000-20000 M3/h |
Cooling Capacity: |
60-80KW |
Warranty: |
1 Year(12 Month With No Artificial Damage) |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Mounting: |
Floor Standing Units |
Condition: |
Brand New |
Type Of Air Supply: |
Chilled Water/Air Cooled Units/Water Cooled |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Product Name: |
Data Center Precision Air Cooling Units(PAC) |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/Printing Factory/Cinema/Supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Blue/Black/Grey/other Custom Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
15000-20000 M3/h |
Brand New 70-80Kw Coolnet Precision Air Conditioning Units For Mobile Stations
Product Introduction Coolnet precision air conditioner can control the temperature difference range to 0.1 degrees Celsius or even higher. Similarly, this series of precision air conditioners can use a larger circulating air volume to reduce the enthalpy difference under a certain cooling capacity, so usually the unit can only operate under a relatively high sensible heat ratio. This is precisely suitable for server rooms and data centers which are placed in plenty of equipment with high demand in heat dissipation.
Benefits |
Introduction of Main Parts
DC inverter compressor EC fan
Dual electronic expansion valve |
Advantages
|
Technical Features
1) Large air volume and small enthalpy difference. The higher the sensible heat ratio of the same heat load, the greater the required air supply volume. This requires that the air conditioning system of the computer room can provide a larger air supply volume.
2) The heat load of the machine room changes greatly. The precise air conditioning system of the computer room must be able to adapt to the change of this load, so that the electronic components can work in the required environmental conditions and ensure the reliability of the circuit function.
3) Reliability. Alarm, automatically use the backup unit or backup control unit to switch the faulty unit or faulty unit. The control system function of the special air conditioner for the computer room is much better than that of the comfort air conditioner.
|
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Certificates
Factory Details
Packing & Delivery
Case