Product Details
Place of Origin: China
Brand Name: Coolnet
Certification: CE ISO
Model Number: Mirco data center
Payment & Shipping Terms
Minimum Order Quantity: 1pcs
Price: USD3000-10000/pcs
Packaging Details: Standard export package
Delivery Time: 20-35 days
Payment Terms: L/C, T/T
Supply Ability: 200 SETS PER MONTH
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet: |
Single Cabinet/Multiple Cabinets |
Cooling: |
DC Inverter Rack Mounted PAC Units |
Refrigerant: |
R134a,R407C,R22,R410A |
Power: |
Rack PDU And UPS |
Operating: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet: |
Single Cabinet/Multiple Cabinets |
Cooling: |
DC Inverter Rack Mounted PAC Units |
Refrigerant: |
R134a,R407C,R22,R410A |
Power: |
Rack PDU And UPS |
Operating: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Rack Data Center For Harsh Working Places With Enclosed Cabinet And Cooling System
Product Introduction
Rack Data Centers are a new generation of IT equipment physical infrastructure designed and produced in line with the development trend and trend of the IT industry. It integrates power, environment, weak current, lightning protection and monitoring systems with a new product concept of cabinet-type computer room. It is suitable for installation in various indoor environments, providing high availability, high reliability and high adaptability to ensure the operation of IT equipment, and it will also continue to escalate with future needs. |
Advantage
Why a rack data center?
1. High availability
2. High efficiency, energy saving and environmental protection
3. Simplify O&M |
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |