Name: |
Container Data Center |
Color: |
White Or Black |
Static Payload: |
1100kg |
Rack Quantities: |
4-10PCS |
Material: |
2.0mm Cold Rolled Steel |
Two Ends Doors: |
Sliding /manual Doors Optional |
Power Input: |
2 City Power+ 1 Generator, Or 1 City Power +1 Generator |
Custom Logo Lable: |
Yes |
Name: |
Container Data Center |
Color: |
White Or Black |
Static Payload: |
1100kg |
Rack Quantities: |
4-10PCS |
Material: |
2.0mm Cold Rolled Steel |
Two Ends Doors: |
Sliding /manual Doors Optional |
Power Input: |
2 City Power+ 1 Generator, Or 1 City Power +1 Generator |
Custom Logo Lable: |
Yes |
20ft 6pcs Racks Prefabricated Computer Room Shipping Container Data Center IDC
Coolnet prefabricated integrated outdoor data center integrates all the infrastructure required for a containerised data center in one container, such as cabinets, power distribution cabinets, UPS, batteries, air conditioning, fire protection, security and monitoring systems and other components. One-stop professional service solves a large number of construction preparation and outsourcing problems for customers, and is the best solution to meet the fast and flexible needs of enterprise-level data centers.
Applications
Feature
High power density: The power density of the mobile data center can be expanded to more than 400 kW, which can accommodate high-density computing equipment. The same space can accommodate six times the number of cabinets in a traditional data center, saving more space and construction costs.
Low PUE: Due to the use of fully enclosed, hot and cold aisles, the consumption of cold air is reduced, and the power utilization rate is greatly improved; the PUE of the modular data center can be lower than 1.25, and the PUE value can be reduced due to the use of FreeCooling technology. to 1.07.
Rapid deployment: The portable data center is free from the problems of large construction volume, difficult management and at least 2 years of traditional data centers. The coolnet data center container is fully prefabricated according to user needs, from factory prefabrication, installation to Delivery only takes 2-3 months.
Intelligent monitoring system: In order to ensure the normal operation of the data center, it can monitor various indicators of the data center environment in real time. Timely record, query and automatic rapid alarm, and realize remote access function at the same time.
PRODUCT PARAMETERS | ICDC-20 | ICDC-20 |
Container Size | 20’HQ | 40’HQ |
Rack Specification | 600*1000(1100)*2000mm | 600*1000(1100)*2000mm |
Single Rack Capacity | 42U | 42U |
Rack Quantity | 4PCS | 8-10PCS |
Single Rack Capacity | 3-10KW | 3-10KW |
IT Equipment Total Capacity | 12-30kw | 24-75KW |
UPS | 25kva*2 N+1 modular UPS | 25kva*4 N+1 modular UPS |
Battery back up time | 5-15mins | 5-20mins |
Cooling | In-row air conditioner | In-row air conditioner |
Monitoring system | YES | YES |
Door Security System | YES | YES |
Fire alarm and gas fire extinguishing system | YES | YES |
Video Monitoring System | YES | YES |
EPO | YES | YES |
Transportability | Support | Support |
Stackable | Support | Support |
Application | Outdoor Type | Outdoor Type |
Diesel Generator Module | Extraposition | Extraposition |
Business cases
Coolnet utilizes existing mature solutions and intelligent maintenance, and achieves the goal of improving resource utilization, saving investment costs, and saving energy and consumption through natural cooling, precision power distribution, cold and hot aisle containment and other energy-saving technologies; Container, flexible deployment, can be quickly deployed to any environment and harsh place, greatly shortening the construction period of the data center. We solved the problem of high overall construction cost and long construction period of our customers.