Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ROHS,ISO
Model Number: HCDC
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: 8000-30000USD per set
Packaging Details: Standard shipping 20/40 ft container with classification society certification
Delivery Time: 15-20days
Payment Terms: L/C, T/T
Supply Ability: 200 sets per month
Name: |
Container Data Center |
Color: |
White Or Black |
Static Payload: |
1100kg |
Rack Quantities: |
4-10PCS |
Material: |
2.0mm Cold Rolled Steel |
Two Ends Doors: |
Sliding /manual Doors Optional |
Power Input: |
2 City Power+ 1 Generator, Or 1 City Power +1 Generator |
Custom Logo Lable: |
Yes |
Name: |
Container Data Center |
Color: |
White Or Black |
Static Payload: |
1100kg |
Rack Quantities: |
4-10PCS |
Material: |
2.0mm Cold Rolled Steel |
Two Ends Doors: |
Sliding /manual Doors Optional |
Power Input: |
2 City Power+ 1 Generator, Or 1 City Power +1 Generator |
Custom Logo Lable: |
Yes |
Integrated Modular Container Data Center All In One Mobile Containerized Data Center
A containerized data center is a standardized, factory-prefabricated and pre-tested modular data center product and customized solution. companies can increase or decrease products according to their own needs. The mobile data center has the characteristics of low construction cost, flexible movement, low energy consumption, high security and rapid deployment. Prefabricated data center can meet the data center application requirements of most small and medium-sized enterprises.
The internal components of the prefab data center include: cabinets, power distribution cabinets, UPS, batteries, air conditioners, fire protection, security and monitoring systems.
Container size: standard 20ft/40ft or non-standard custom size
Applications
Enterprise: Small Data Center
Operator: Small IT room, small IDC, DR room and edge DC
Government: Smart City, Safe City Data Center
Education: University/Institute Data Center
Energy: Production/Investigation Field Data Center
Finance: Backup data center
Transportation: Airport/Railway/Port without housing power supply and distribution
Advantage
Scalability :A scalable, modular data center solution that companies can expand as needed. Energy saving, low PUE.
Flexible deployment: It takes 18-24 months to complete the traditional data center, and our new generation container data center only takes 2-3 months, it can be used when plugged in.
In-row air conditioner - close to the heat source, the cold aisle/hot aisle is closed, which can completely avoid the loss of cooling capacity caused by the mixing of cold and hot air, and water cooling.
High power density: The power density can be expanded to more than 400 kilowatts, which can accommodate high-density computing equipment. The same space can accommodate six times the number of cabinets in a traditional data center, saving more space and construction costs.
PRODUCT PARAMETERS | ICDC-20 | ICDC-20 |
Container Size | 20’HQ | 40’HQ |
Rack Specification | 600*1000(1100)*2000mm | 600*1000(1100)*2000mm |
Single Rack Capacity | 42U | 42U |
Rack Quantity | 4PCS | 8-10PCS |
Single Rack Capacity | 3-10KW | 3-10KW |
IT Equipment Total Capacity | 12-30kw | 24-75KW |
UPS | 25kva*2 N+1 modular UPS | 25kva*4 N+1 modular UPS |
Battery back up time | 5-15mins | 5-20mins |
Cooling | In-row air conditioner | In-row air conditioner |
Monitoring system | YES | YES |
Door Security System | YES | YES |
Fire alarm and gas fire extinguishing system | YES | YES |
Video Monitoring System | YES | YES |
EPO | YES | YES |
Transportability | Support | Support |
Stackable | Support | Support |
Application | Outdoor Type | Outdoor Type |
Diesel Generator Module | Extraposition | Extraposition |
Customer value
The container itself is the carrier of the data center. Compared with the computer room building, the cost is very low.
Flexible and transportable, it can be easily deployed and transported to your desired location within weeks.
Comprehensive visualization of 3D computer room on-site management, intelligent monitoring and fault alarm, real-time monitoring of fire protection, access control, electricity and other equipment.