Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Hot Cold Aisle Containment > Server Room Integrated Micro Module Data Center With PAC And Modular UPS

Server Room Integrated Micro Module Data Center With PAC And Modular UPS

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ROHS,ISO

Model Number: IMDC

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: 8000-30000USD per set

Packaging Details: Packed in plywooden case and CTN

Delivery Time: 15-20days

Payment Terms: L/C, T/T

Supply Ability: 200 sets per month

Get Best Price
Highlight:

Cold Aisle Micro Data Centers

,

PAC Module Data Center

,

2.0mm Cold Rolled Steel Data Center

Name:
Data Center Rack Cold Aisle Containment
Material:
2.0mm Cold Rolled Steel
Hot Air Containment:
Included
Cabinet Standard::
ANS/EIA RS-310-D
Color:
Grey Or Black
Two Ends Doors:
Sliding /manual Doors Optional
Static Payload:
1100kg
Custom Logo Lable:
Yes
Name:
Data Center Rack Cold Aisle Containment
Material:
2.0mm Cold Rolled Steel
Hot Air Containment:
Included
Cabinet Standard::
ANS/EIA RS-310-D
Color:
Grey Or Black
Two Ends Doors:
Sliding /manual Doors Optional
Static Payload:
1100kg
Custom Logo Lable:
Yes
Server Room Integrated Micro Module Data Center With PAC And Modular UPS

Server Room Integrated Micro Module Data Center with Precision Air Conditioning and Modular UPS

 

Product Introduction                                     

Coolnet's modular solutions approach simplifies the complex environment of the data center by integrating the most comprehensive range of power, precision cooling, monitoring and management technologies.

Modular data center has adopted some of industry-best practices to deliver “Invest while growing” infrastructures that overcome challenges in capital inefficiencies and uncertain IT capacity demands.

 

Benifits                                                        

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 0

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 1

Scope of Application                                        

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 2

  • Branches and networks of large enterprises
  • Government
  • Education

Characteristics                                              

 

One-button sunroof, automatic reset

There is no need to manually close the sunroof, and it is convenient and quick to automatically reset with one key, saving debugging, maintenance, and maintenance time.

 

Cooling solution

Air-cooled module solution

Applicable to various medium and small data centers, such as: operator data centers, data centers of various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.

Chilled water module

It is suitable for all kinds of large and medium data centers with chilled water hosts, such as: Internet data centers, operator data centers, data centers in various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.

 

Efficient modular UPS

High density. A single cabinet supports a maximum 15 kW to meets various customer requirements. Modular UPS adopts the most advanced technology, realizes modular design, reduces the initial purchase cost, and meets the later equipment expansion needs and capacity expansion.

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 3

 

Main Basic Unit Introduction

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 4

Aisle Containment -Modular design

Adopting modular unit design concept, each unit can be installed and disassembled independently, and can be closely connected with adjacent units, which is convenient for disassembly and assembly; at the same time, it is also suitable for maintenance and management of other equipment on the channel.

 

Good sealing

All unit modules in the hot and cold aisle system are connected precisely, and the parts are sealed with good sealing tops or sponge strips, which not only maintains the aesthetics, but also prevents the leakage of cold air in the cold aisle.

 

Good light transmission

The system is composed of toughened glass with strong light transmittance.

 

Monitoring System

The monitoring system system has the characteristics of simple configuration, strong access, and high reliability. It can manage all power, environment, and cooling in data center, integrate mainstream brand access control, video and other security systems, through distributed collection, high concurrent processing capabilities Meet the needs of networked monitoring and management of multiple computer rooms, allowing data center operation and maintenance personnel to control the operation safety of the computer room in real time.

 

End gate

(1) The end doors of the aisle are divided into sliding doors and double doors, which can be selected according to customer needs.

(2) Sliding door size: height × width × depth = 2050mm × 1200mm × 42mm.
The sliding door adopts a sliding structure, the cabinet is used as the carrier, and the upper and lower rails are installed to ensure the independence of the closed channel system. The door panel is bent from 1.5mm cold-rolled steel plate, and tempered glass is installed in the middle to ensure the visibility of the area in the passage.

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 5

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 6

Technical Specification                                            

Equipment System Item Parameter
System Dimension 1200mm enclosed cold/hot aisle dual-row cabinets
    1200mm enclosed cold/hot aisle Single-row cabinets
  Rack Quantity Dual Row Racks:≤48,Single Row Racks:≤24
Rack Dimensions 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
  Protection Class IP20
Enclosed Aisle Skylight 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and Distribution Dimension 600mm(W)*1200mm(D)*2000mm(H)
  UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
  Battery 40AH~240AH/12V Valve Regulated Lead Acid Battery
Cooling Indoor Unit Size 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
  Cooling Capacity Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
  Power Supply 3Phase 380VAC,50Hz
  Air Supply Front Supply
  Type Enclosed Hot/Cold Aisle
  Protection IP20
Monitoring System Monitoring Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm
  Equipment monitoring Power supply, battery, power distribution, air conditioning

 

Certificates                                           

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 7

 

Factory Details                                       

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 8

 

Parking & Delivery                                     

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 9

 

Cases                                          

Server Room Integrated Micro Module Data Center With PAC And Modular UPS 10