Name: |
Container Data Center |
Material: |
2.0mm Cold Rolled Steel |
Hot Air Containment: |
Included |
Cabinet Standard: |
ANS/EIA RS-310-D |
Color: |
White Or Black |
Two Ends Doors: |
Sliding /manual Doors Optional |
Static Payload: |
1100kg |
Custom Logo Lable: |
Yes |
Name: |
Container Data Center |
Material: |
2.0mm Cold Rolled Steel |
Hot Air Containment: |
Included |
Cabinet Standard: |
ANS/EIA RS-310-D |
Color: |
White Or Black |
Two Ends Doors: |
Sliding /manual Doors Optional |
Static Payload: |
1100kg |
Custom Logo Lable: |
Yes |
All In One Shipping Containerized Data Center Solution with In Row Precision Air Conditioner
Coolnet I-Container series Prefabricated outdoor data center infrastructure solution that integrates functions such as power supply and distribution, temperature control, cabinets, management, fire protection, lightning protection and grounding, and is used to carry IT equipment and provide stable, reliable, and energy-saving power ring system. Applicable to multiple industries and scenarios, it has minimalist, green, intelligent and safe features.
The internal components of the container data center include: cabinets, power distribution cabinets, UPS, batteries, air conditioners, fire protection, security and monitoring systems.
Container size: standard 20ft/40ft or non-standard custom size.
Applications
Feature
Redundancy
In the event of a failure, the remaining units will continue to function normally, keeping your business running and protecting your uptime.
Scalability
Scalable and modular solutions that allow companies can quickly grow their data capacity as needed to meet the demands of their customers.
In-row air conditioning
Close to the heat source, the cold aisle/hot aisle is closed, which can completely avoid the loss of cooling capacity caused by the mixing of cold and hot air, water cooling.
Customer value
Mobile and flexible
Due to the integration of the product, Prefabricated data center can be transferred in time according to different site conditions, which is convenient and fast. Prefab data center have extremely low requirements on the use environment, and are very suitable for deserts, tidal flats, high altitudes, severe cold and other environments.
Rapid deployment
Containerized data center get rid of the problems of large construction volume and difficult management of traditional data centers, and are fully prefabricated in factories according to user needs, so the on-site deployment period can be shortened to 2-3 months
Data center container customization
Portable data center can be customized on demand, 20 or 40ft containerized data center, support customization. The standard container production process is used for welding and anti-corrosion, and it can be processed and produced according to different specifications to meet the customized needs of different projects.
PRODUCT PARAMETERS | ICDC-20 | ICDC-20 |
Container Size | 20’HQ | 40’HQ |
Rack Specification | 600*1000(1100)*2000mm | 600*1000(1100)*2000mm |
Single Rack Capacity | 42U | 42U |
Rack Quantity | 4PCS | 8-10PCS |
Single Rack Capacity | 3-10KW | 3-10KW |
IT Equipment Total Capacity | 12-30kw | 24-75KW |
UPS | 25kva*2 N+1 modular UPS | 25kva*4 N+1 modular UPS |
Battery back up time | 5-15mins | 5-20mins |
Cooling | In-row air conditioner | In-row air conditioner |
Monitoring system | YES | YES |
Door Security System | YES | YES |
Fire alarm and gas fire extinguishing system | YES | YES |
Video Monitoring System | YES | YES |
EPO | YES | YES |
Transportability | Support | Support |
Stackable | Support | Support |
Application | Outdoor Type | Outdoor Type |
Diesel Generator Module | Extraposition | Extraposition |
Business cases
Coolnet utilizes existing mature solutions and intelligent maintenance, and achieves the goal of improving resource utilization, saving investment costs, and saving energy and consumption through natural cooling, precision power distribution, cold and hot aisle containment and other energy-saving technologies; Container, flexible deployment, can be quickly deployed to any environment and harsh place, greatly shortening the construction period of the data center. We solved the problem of high overall construction cost and long construction period of our customers.