Product Details
Place of Origin: China
Brand Name: Coolnet
Certification: CE ISO
Model Number: Mirco data center
Payment & Shipping Terms
Minimum Order Quantity: 1pcs
Price: USD3000-10000/pcs
Packaging Details: Standard export package
Delivery Time: 20-35 days
Payment Terms: L/C, T/T
Supply Ability: 200 SETS PER MONTH
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet: |
Two Cabinets |
Cooling: |
DC Inverter Rack Mounted PAC Units |
Operating: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Voltage: |
380v/220v,110-220v/50-60Hz,220V/50Hz |
Cabinet: |
Two Cabinets |
Cooling: |
DC Inverter Rack Mounted PAC Units |
Operating: |
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
Simple And Deeply Integrated Rack Data Center For Small And Medium Server Rooms
Product Introduction
Coolnet Rack Data Center refers to a product in which devices with more functions are installed in the cabinet. The micro-module integrated cabinet system is for safe city police station outlets, small and medium-sized enterprises, large enterprise branch offices, telecommunications business halls, bank outlets, railway communication computer rooms, and highway toll collection, computer rooms, etc., providing one-stop solutions for air conditioners, UPS, cabinets, PDUs, KVMs, and power environment monitoring systems. |
Technical Features
Convenient
Efficient
|
Advantage
|
Application
|
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |
Factory View
Case