Integrated Rack Data Center Solutions For Computer Rooms In Edging Computing
Product Introduction
Coolnet rack data center integrates power supply, environment, weak current, lightning protection, and monitoring systems, and has a new product concept of cabinet-type computer room. It has the characteristics of rapid deployment, precise cooling, intelligence, visualization, and modularization. It has low requirements on the external environment, strong availability, high reliability and good adaptability, which can provide stable and safe guarantee for the operation of IT equipment, and will continue to update with future needs.
Benefits
|
Feature
Power Distribution System It consists of UPS, battery, power distribution unit and PDU. The UPS is installed in a standard 19-inch rack, with high frequency double conversion, high efficiency, suitable for a wide range of voltage and frequency, and compatible with generator access. Safe and reliable lead-acid batteries are used, with long life and low risk. Power distribution unit rack-mounted design, safe and reliable quality, easy maintenance.
Monitoring System
The intelligent monitoring system has the function of centralized management, and supports the remote management and maintenance of the monitoring system. The remote operation interface is consistent with the local operation interface. The monitoring system is mainly composed of various layers of the modular data center infrastructure, such as power distribution, cooling, security and environmental systems and other components in real-time monitoring.
|
Advantage
Wisdom
Efficient
|
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |