42U Integrated Rack Data Center Solutions For Edging Computing

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE ISO

Model Number: Mirco data center

Payment & Shipping Terms

Minimum Order Quantity: 1pcs

Price: USD3000-10000/pcs

Packaging Details: Standard export package

Delivery Time: 20-35 days

Payment Terms: L/C, T/T

Supply Ability: 200 SETS PER MONTH

Get Best Price
Highlight:

42U Integrated Data Center Solutions

,

DC Inverter Rack Data Center

,

PAC Units Integrated Data Center

Voltage:
380v/220v,110-220v/50-60Hz,220V/50Hz
Cabinet:
Multiple Cabinets
Cooling:
DC Inverter Rack Mounted PAC Units
Power:
Rack PDU And UPS
Voltage:
380v/220v,110-220v/50-60Hz,220V/50Hz
Cabinet:
Multiple Cabinets
Cooling:
DC Inverter Rack Mounted PAC Units
Power:
Rack PDU And UPS
42U Integrated Rack Data Center Solutions For Edging Computing

Integrated Rack Data Center Solutions For Computer Rooms In Edging Computing

 

Product Introduction                                                           

Coolnet rack data center integrates power supply, environment, weak current, lightning protection, and monitoring systems, and has a new product concept of cabinet-type computer room. It has the characteristics of rapid deployment, precise cooling, intelligence, visualization, and modularization. It has low requirements on the external environment, strong availability, high reliability and good adaptability, which can provide stable and safe guarantee for the operation of IT equipment, and will continue to update with future needs.

 

 

 

Benefits                                                                                  

42U Integrated Rack Data Center Solutions For Edging Computing 0

42U Integrated Rack Data Center Solutions For Edging Computing 1

   

Feature                                                                                    

42U Integrated Rack Data Center Solutions For Edging Computing 2

 

 

Power Distribution System
 

It consists of UPS, battery, power distribution unit and PDU. The UPS is installed in a standard 19-inch rack, with high frequency double conversion, high efficiency, suitable for a wide range of voltage and frequency, and compatible with generator access. Safe and reliable lead-acid batteries are used, with long life and low risk. Power distribution unit rack-mounted design, safe and reliable quality, easy maintenance.

 

Monitoring System

 

The intelligent monitoring system has the function of centralized management, and supports the remote management and maintenance of the monitoring system. The remote operation interface is consistent with the local operation interface. The monitoring system is mainly composed of various layers of the modular data center infrastructure, such as power distribution, cooling, security and environmental systems and other components in real-time monitoring.

 

 

Advantage                                                                                

 

Wisdom

 

  • When there are multiple outlets, unified monitoring, remote access, and centralized operation and maintenance management are optional;
  • Precise energy efficiency management, clear electricity consumption;
  • All-round alarm interface, support SMS sending, timely understanding of equipment abnormalities

 

Efficient

 

  • Close the hot and cold air flow to avoid the mixed flow of air flow, thereby improving the cooling efficiency and reducing the PUE;
  • Optional high-frequency rack UPS, or modular UPS, efficient operation;
  • Near-end cooling to reduce air loss;
  • Adopt DC inverter compressor and stepless speed regulating EC fan, which can run efficiently under load

 

42U Integrated Rack Data Center Solutions For Edging Computing 3

 

Technical Parameter                                                                  

 

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 