Name: |
Container Data Center |
Hot Air Containment: |
Included |
Color: |
White Or Black |
Static Payload: |
1100kg |
Material: |
2.0mm Cold Rolled Steel |
Cabinet Standard: |
ANS/EIA RS-310-D |
Two Ends Doors: |
Sliding /manual Doors Optional |
Custom Logo Lable: |
Yes |
Name: |
Container Data Center |
Hot Air Containment: |
Included |
Color: |
White Or Black |
Static Payload: |
1100kg |
Material: |
2.0mm Cold Rolled Steel |
Cabinet Standard: |
ANS/EIA RS-310-D |
Two Ends Doors: |
Sliding /manual Doors Optional |
Custom Logo Lable: |
Yes |
40ft Mobile Portable Shipping Prefabricated Data Center Container For Telecom
Coolnet I-Container series containerized outdoor data center infrastructure solution that integrates functions such as power supply and distribution, temperature control, cabinets, management, fire protection, lightning protection and grounding, and is used to carry IT equipment and provide stable, reliable, and energy-saving power ring system. Applicable to multiple industries and scenarios, it has minimalist, green, intelligent and safe features.
The internal components of the container data center include: cabinets, power distribution cabinets, UPS, batteries, air conditioners, fire protection, security and monitoring systems.
Container size: standard 20ft/40ft or non-standard customized size.
Feature
Intelligent monitoring system: In order to ensure the normal operation of the data center, it can monitor various indicators of the data center environment in real time. Timely record, query and automatic rapid alarm, and realize remote access function at the same time.
Low PUE: Due to the use of fully enclosed, hot and cold aisles, the consumption of cold air is reduced, and the power utilization rate is greatly improved; the PUE of the modular data center can be lower than 1.25, and the PUE value can be reduced due to the use of FreeCooling technology. to 1.07.
High power density: The power density of the modular data center can be expanded to more than 400 kW, which can accommodate high-density computing equipment. The same space can accommodate six times the number of cabinets in a traditional data center, saving more space and construction costs.
Rapid deployment: The portable data center solution is free from the problems of large construction volume, difficult management and at least 2 years of traditional data centers. The coolnet data center container is fully prefabricated according to user needs, from factory prefabrication, installation to Delivery only takes 2-3 months.
PRODUCT PARAMETERS | ICDC-20 | ICDC-20 |
Container Size | 20’HQ | 40’HQ |
Rack Specification | 600*1000(1100)*2000mm | 600*1000(1100)*2000mm |
Single Rack Capacity | 42U | 42U |
Rack Quantity | 4PCS | 8-10PCS |
Single Rack Capacity | 3-10KW | 3-10KW |
IT Equipment Total Capacity | 12-30kw | 24-75KW |
UPS | 25kva*2 N+1 modular UPS | 25kva*4 N+1 modular UPS |
Battery back up time | 5-15mins | 5-20mins |
Cooling | In-row air conditioner | In-row air conditioner |
Monitoring system | YES | YES |
Door Security System | YES | YES |
Fire alarm and gas fire extinguishing system | YES | YES |
Video Monitoring System | YES | YES |
EPO | YES | YES |
Transportability | Support | Support |
Stackable | Support | Support |
Application | Outdoor Type | Outdoor Type |
Diesel Generator Module | Extraposition | Extraposition |
Applications