Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Hot Cold Aisle Containment > Integrated Computer Room IDC Modular Data Center Cold Aisle High Density

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ROHS,ISO

Model Number: IMDC

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: 8000-30000USD per set

Packaging Details: Packed in plywooden case and CTN

Delivery Time: 15-20days

Payment Terms: L/C, T/T

Supply Ability: 200 sets per month

Get Best Price
Highlight:

Integrated Data Center Cold Aisle

,

IDC Modular Data Center Cold Aisle

,

High Density Data Center Cold Aisle

Name:
Data Center Rack Cold Aisle Containment
Hot Air Containment:
Included
Color:
Grey Or Black
Static Payload:
1100kg
Material:
2.0mm Cold Rolled Steel
Cabinet Standard:
ANS/EIA RS-310-D
Two Ends Doors:
Sliding /manual Doors Optional
Custom Logo Lable:
Yes
Name:
Data Center Rack Cold Aisle Containment
Hot Air Containment:
Included
Color:
Grey Or Black
Static Payload:
1100kg
Material:
2.0mm Cold Rolled Steel
Cabinet Standard:
ANS/EIA RS-310-D
Two Ends Doors:
Sliding /manual Doors Optional
Custom Logo Lable:
Yes
Integrated Computer Room IDC Modular Data Center Cold Aisle High Density

Integrated Computer Room IDC Modular Data Center, All In One High Density Micro Data Center

 

Product Introduction                               

Micro module data center includes cooling modules, distribution modules and power supply, as well as modules for network, wiring, monitoring, and fire fighting.
Micro-module data center is designed according to the principles of high efficiency, energy saving, and optimized management.
The micro data center has external power supply interfaces, cooling interfaces, network interfaces, and The integrated wiring interface is reserved for the overhead weak and strong current tanks, and the In Row air conditioning is used for cooling, which achieves a high sensible heat ratio of 100%, effectively reducing the overall humidification and dehumidification energy consumption of the data center, and the In Row air conditioner circulates airflow The road is the shortest, increasing the heat density of the data center under the premise of effective cooling, and realizing the energy-saving cooling of the data center.

 

Applications                                              

Single module Solution :
Small and medium data centers. For data center needs of small and medium enterprises and branch offices of large enterprises.

Multi-module solution:
For the needs of large-scale data centers in IDC, large enterprises, financial centers, governments, military, supercomputer centers, education, medical and other industries.

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 0

 Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 1
Features                                         

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 2 Efficient modular UPS
High density. A single cabinet supports a maximum 15 kW to meets various customer requirements. Can be installed on a concrete floor, which greatly simplifies the corresponding engineering tasks.

Smart monitoring system
Centralized monitoring platform makes us know the data center environment, power and temperature & humidity status in real-time.
Powerful reporting capabilities.
365 days 7x24-hour unattended, remote monitoring. Minimize IT operation and maintenance costs.
The dynamic environment monitoring system monitors the infrastructure in an all-round way, alerts abnormal conditions in time, and is safe and secure.


Fast deployment
Full integration of IT cabinet, UPS, battery, power distribution and precision cooling system. The main body of the building and the basic water and electricity construction are completed at one time, and the micro-modules are flexibly deployed as needed. Modular components following international standards are quick to play within 7 days and greatly shorten the business on line cycle.

Cooling solution
Air-cooled module solution

Applicable to various medium and small data centers, such as: operator data centers, data centers of various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.
Chilled water module
It is suitable for all kinds of large and medium data centers with chilled water hosts, such as: Internet data centers, operator data centers, data centers in various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.

Main Basic Unit Introduction                                          

 

Aisle Containment -Modular design
Adopting modular unit design concept, each unit can be installed and disassembled independently, and can be closely connected with adjacent units, which is convenient for disassembly and assembly; at the same time, it is also suitable for maintenance and management of other equipment on the channel.
Good sealing
All unit modules in the hot and cold aisle system are connected precisely, and the parts are sealed with good sealing tops or sponge strips, which not only maintains the aesthetics, but also prevents the leakage of cold air in the cold aisle.
Good light transmission
The system is composed of toughened glass with strong light transmittance.

Power Supply- Modular UPS
According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power.

Cooling System - In Row Air Conditioning Unit
Inverter In Row air conditioners are tailor-made high-density cabinets, adopts advanced frequency conversion technology and uses the environmentally friendly refrigerant R410A. The output cooling capacity is adjusted in real time according to the change of the detected load, to avoid frequent start and stop, and to ensure the temperature of the computer room environment.
Compared with fixed frequency air conditioners, the annual energy saving rate of variable frequency inter-train air conditioners can reach 29%.

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 3

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 4
Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 5
 

Technical Specification                                            

Equipment System Item Parameter
System Dimension 1200mm enclosed cold/hot aisle dual-row cabinets
    1200mm enclosed cold/hot aisle Single-row cabinets
  Rack Quantity Dual Row Racks:≤48,Single Row Racks:≤24
Rack Dimensions 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
  Protection Class IP20
Enclosed Aisle Skylight 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and Distribution Dimension 600mm(W)*1200mm(D)*2000mm(H)
  UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
  Battery 40AH~240AH/12V Valve Regulated Lead Acid Battery
Cooling Indoor Unit Size 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
  Cooling Capacity Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
  Power Supply 3Phase 380VAC,50Hz
  Air Supply Front Supply
  Type Enclosed Hot/Cold Aisle
  Protection IP20
Monitoring System Monitoring Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm
  Equipment monitoring Power supply, battery, power distribution, air conditioning

 

Certificates                                                  

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 6

 

Factory Details                                       

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 7

 

Parking & Delivery                                      

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 8

 

Cases                                          

Integrated Computer Room IDC Modular Data Center Cold Aisle High Density 9