Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ROHS,ISO
Model Number: IMDC
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: 8000-30000USD per set
Packaging Details: Packed in plywooden case and CTN
Delivery Time: 15-20days
Payment Terms: L/C, T/T
Supply Ability: 200 sets per month
Name: |
Data Center Rack Cold Aisle Containment |
Hot Air Containment: |
Included |
Color: |
Grey Or Black |
Static Payload: |
1100kg |
Material: |
2.0mm Cold Rolled Steel |
Cabinet Standard: |
ANS/EIA RS-310-D |
Two Ends Doors: |
Sliding /manual Doors Optional |
Custom Logo Lable: |
Yes |
Name: |
Data Center Rack Cold Aisle Containment |
Hot Air Containment: |
Included |
Color: |
Grey Or Black |
Static Payload: |
1100kg |
Material: |
2.0mm Cold Rolled Steel |
Cabinet Standard: |
ANS/EIA RS-310-D |
Two Ends Doors: |
Sliding /manual Doors Optional |
Custom Logo Lable: |
Yes |
Intelligent Server Networking Micro Data Center, Modular Data Center
Product Introduction To meet the demand of high power density and low PUE in the future data center, COOLNET new generation smart micro data center solution with complete integration of power supply, cooling system, distribution systems, battery, fire-protection, cabinets and etc. With modular design for all components, factory pre-installation, pre-test and whole-package transportation, field installation requires only basic combined cabinet assembly. The closed hot and cold aisles will achieve higher cooling efficiency. All components are factory produced, more suitable for equipment room installation configuration.
Applications Single module Solution : Small and medium data centers. For data center needs of small and medium enterprises and branch offices of large enterprises.
Multi-module solution: For the needs of large-scale data centers in IDC, large enterprises, financial centers, governments, military, supercomputer centers, education, medical and other industries. |
Features
Green energy saving At present, the cost of electricity usage in data centers accounts for the largest proportion of life-time TCO. The micro-module power conversion rate is as high as 95%. Due to the standardized interface and micro-module architecture, it can greatly save power and achieve system energy saving.
Intelligent fire safe system Alerts personnel and drops ceiling panels based on temperature to enable fire suppressions system in the room to extinguish the fire. Once fire signal alarm in room, the top plate will open automatically, and fire extinguishing gas enter the aisle.
Precision cooling device Inline Cooler -CRV+ responds faster to dynamic loads. Efficiently integrates smart channel logic control at higher return air temperatures with the most efficient/accurate thermal control algorithm for maximum energy savings. |
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |