In Row Air Conditioning For Data Centers With Limited Equipment Room

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: XR023A, XR040A

Payment & Shipping Terms

Minimum Order Quantity: 1Unit

Price: USD1800-30000/Unit

Packaging Details: Packed in plywood case, standard export package

Delivery Time: 20-35Working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Axial Fan In Row Air Conditioning

,

Data Centers In Row Air Conditioning

,

Data Centers Inrow Cooling Unit

Name:
In-Row Air Conditioning Units
Mounting:
Floor Standing
Type:
Row Based In Row Precision Air Conditioning Unit
Voltage:
380/400 VAC,230 VAC,220V
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Airflow:
2000~50000 M3/h
Refrigerant:
R410A/ R407C
Application:
Data Center, IT Room , Computer Room, Server Room
Name:
In-Row Air Conditioning Units
Mounting:
Floor Standing
Type:
Row Based In Row Precision Air Conditioning Unit
Voltage:
380/400 VAC,230 VAC,220V
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Airflow:
2000~50000 M3/h
Refrigerant:
R410A/ R407C
Application:
Data Center, IT Room , Computer Room, Server Room
In Row Air Conditioning For Data Centers With Limited Equipment Room

In Row Air Conditioning For Data Centers With Limited Equipment Room

 

Product Introduction                                 

In-row air conditioners are also called in-row air cooling units, or in-row refrigeration units. They are precision refrigeration systems specifically designed for high-heat-density racks. They are placed directly between the rows of server cabinets and dissipate heat directly near the heat source. Generally, the compressors of air-cooled in-row airconditioning units use variable-capacity digital scroll compressors, and the fans use EC fans. The whole machine can adjust the cooling capacity output according to the heat load in the channel. In-row air cooling units are widely used in places, such as condition containerized data centers, various modular data centers, data centers with low PUE requirements, local hot spots in computer rooms, high heat density areas in medium and large computer rooms, and computer rooms Data centers with tight area, etc.

 

Applications                                      

  • Single row cabinet data center
  • Single row cabinet and closed cold aisle data center
  • Closed hot aisle data center
  • Modular DC
  • Container type DC
  • DC with low PUE

 

In Row Air Conditioning For Data Centers With Limited Equipment Room 0

In Row Air Conditioning For Data Centers With Limited Equipment Room 1 

Features                                     

In Row Air Conditioning For Data Centers With Limited Equipment Room 2

Close to the heat source cooling, short air flow path, small cooling loss.

Suitable for high return air temperature, high heat equipment air temperature matching high.

 

Super high efficiency, energy saving, low operating cost.

High sensible heat ratios do not result in excessive dehumidification.

Super long life design,continuous operation for 24 hours and 365 days, design life for 10 years.

 

Easy maintenance: The main components are easy to remove and the fan is hot swappable. The front and rear doors are maintained in accordance with the cabinet maintenance habits, without side maintenance.

 

Multiple efficient backward tilt centrifuges are directly connected to fans, with redundant air volume design, and each fan operates at a better efficiency point.

 

The fans are in a full coverage layout that covers the entire unit facade. The air distribution in and out of the machine is more uniform, which is more conducive to improving energy efficiency and cooling effect.

 

The direct expander uses compressors with high energy efficiency and reliability and EC compressors. The cooling capacity can be adjusted according to the equipment load, thus saving energy and efficiency.

 

The evaporator adopts full cabinet design to maximize the use of space in the unit, so that the heat exchange area is larger. Adopting full coverage fan, the heat exchange effect is better, the cold transport is more stable and uniform.

 

 

Technical Parameter                                             

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 