41.9kW Precision Air Conditioning Units For Computer Room And Data Center

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYA T41D/U

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 3000-30000 USD/unit

Packaging Details: Standard export package

Delivery Time: 20-45 working days

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

41.9KW Precision Ac Unit

,

R410A Data Center Precision Air Conditioning

Cooling Capacity:
41.9KW
Operating Voltage:
380/400 VAC, 230 VAC, 220V
Warranty:
1 Year
Refrigerant:
R410A
Application:
Computer Room, Data Center, Industrial, Heat Recovery, Adjust Cold/heat/humidity
Color:
Black/Grey White/other Customized Colors
Airflow:
Upflow/Downflow
Fan Section:
Centrifugal EC FAN
Cooling Capacity:
41.9KW
Operating Voltage:
380/400 VAC, 230 VAC, 220V
Warranty:
1 Year
Refrigerant:
R410A
Application:
Computer Room, Data Center, Industrial, Heat Recovery, Adjust Cold/heat/humidity
Color:
Black/Grey White/other Customized Colors
Airflow:
Upflow/Downflow
Fan Section:
Centrifugal EC FAN
41.9kW Precision Air Conditioning Units For Computer Room And Data Center

Optimize​ Your Unit Selection 40kW Various Cooling System For Computer Room And Data Center

 

Introduction                 

      

The 26kW–102kW range is covered by the Cyber Master series of medium and large air-cooled room air conditioners. R410a is the chosen refrigerant in this situation.

Based on the independence of the heat exchange, air supply, and control modules, maintenance may be done continuously. The horizontal air supply under the floor may be realized with a sunken construction, and there is less resistance loss.

 

Applications                    

  • IDC, Computer room
  • Network equipment room, Server room, communication equipment room
  • Monitoring room, Power distribution room, and battery room
  • High-precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, High precision workshop

41.9kW Precision Air Conditioning Units For Computer Room And Data Center 0

 

Air Supply Method

                    

41.9kW Precision Air Conditioning Units For Computer Room And Data Center 1          

Technical Features         

             

41.9kW Precision Air Conditioning Units For Computer Room And Data Center 2

Evaporator

Unique evaporator design with a large heat exchange area and high heat transfer efficiency.

 

Heating

PTC electric heater with high conduction efficiency, equipped with an overheat protection device, efficient, reliable, and safe, Heater quantity can be customized.

 

Condenser

The air-cooled condenser is made of marine-grade corrosion-resistant materials, has outstanding rigidity and anti-corrosion functions, and is accustomed to various environmental conditions. Fully adjustable speed electric fans are used to achieve energy saving and low noise.

 

Air pressure switch

Configurable filter blockage and airflow loss are two functions of the air pressure switch for accurate monitoring of filter status and fan status to ensure normal operation of the unit.

Advantages       

                              

  • 7" color touch controller, easy and convenient to operate
  • With 3 levels of passwords, set different operation levels
  • Standard RS485 interface, flexible networking monitoring mode
  • With 500 large capacity fault alarm records storage function
  • Can display the whole machine and parts running status and running time
  • The modular design of the unit, ultra-narrow body, occupies less space
  • Uniform module structure of all units, strong commonality of parts
  • The width of the unit adopts the combination of body and compressor cabinet
  • Width (mm): 915/1315/1790/2190
  • Smallest footprint in the industry
  • The sensible heat ratio is up to 91%.
  • The compressor energy efficiency ratio is over 3.1, and chilled water
  • The unit’s cooling energy efficiency is larger than 25.
  • The optimal and high-efficiency compressor and fans.
41.9kW Precision Air Conditioning Units For Computer Room And Data Center 3

 

Technical Parameters         

      

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity:24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180
 

 